Accelerator mass spectrometry on SIRIUS: new 6MV spectrometer at ANSTO

dc.contributor.authorWilcken, KMen_AU
dc.contributor.authorFink, Den_AU
dc.contributor.authorHotchkis, MACen_AU
dc.contributor.authorGarton, Den_AU
dc.contributor.authorButton, Den_AU
dc.contributor.authorMann, Men_AU
dc.contributor.authorKitchen, Ren_AU
dc.date.accessioned2020-06-09T02:57:22Zen_AU
dc.date.available2020-06-09T02:57:22Zen_AU
dc.date.issued2016-07-03en_AU
dc.date.statistics2020-05-28en_AU
dc.description.abstractAs a part of Australian Federal Government funding in 2009 to establish a centre for accelerator science a new 6 MV state of the art accelerator – SIRIUS – was purchased. The system is now commissioned and comprises ion sources and beam lines to cater for a wide variety of both IBA and AMS applications. The ion source used for AMS (MC-SNICS) is the latest incarnation followed by 45 degree spherical ESA(R=0.3 m) and double focusing injection magnet (R=1 m, ME=20) prior the accelerator. At the terminal we have a choice of 2 stripper gasses and/or stripper foils. The high-energy spectrometer for AMS consists of a 1.27 m radius analyzing magnet with ME=176, 45 degree ESA (R=3.81m), followed by a switching magnet and 3 beam lines: one with a standard multianode ionization chamber; one with an absorber cell in front of the detector; whereas the third beam line has a time-of- ight detector. Details of the instrument design and performance data for 10Be, 26Al and 36Cl will be presented. © The Authorsen_AU
dc.identifier.citationWilcken, K., Fink, D., Hotchkis, M., Garton, D., Button, D., Mann, M., & Kitchen, R. (2016). Accelerator Mass Spectrometry on SIRIUS: new 6MV spectrometer at ANSTO. Paper presented at 12th European Conference on Accelerators in Applied Research and Technology (ECAART12) hosted by the Department of Physics of the University of Jyväskylä, Finland, 3rd – 8th July, 2016.en_AU
dc.identifier.conferenceenddate8 July 2016en_AU
dc.identifier.conferencename12th European Conference on Accelerators in Applied Research and Technology (ECAART12)en_AU
dc.identifier.conferenceplaceJyväskylä, Finlanden_AU
dc.identifier.conferencestartdate3 July 2016en_AU
dc.identifier.govdoc9624en_AU
dc.identifier.isbn9789513967000en_AU
dc.identifier.urihttps://jyx.jyu.fi/bitstream/handle/123456789/52723/ecaart12-abstractbook-online.pdf?sequence=1&isAllowed=yen_AU
dc.identifier.urihttp://apo.ansto.gov.au/dspace/handle/10238/9520en_AU
dc.language.isoenen_AU
dc.publisherUniversity of Jyväskylä, Finlanden_AU
dc.subjectMass spectroscopyen_AU
dc.subjectANSTOen_AU
dc.subjectAustraliaen_AU
dc.subjectIon beamsen_AU
dc.subjectBeamsen_AU
dc.subjectAcceleratorsen_AU
dc.titleAccelerator mass spectrometry on SIRIUS: new 6MV spectrometer at ANSTOen_AU
dc.typeConference Presentationen_AU
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
ecaart12-abstractbook-online.pdf
Size:
10.57 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: