Non-rigid registration method for mouse whole body skeleton registration.

dc.contributor.authorXiao, Den_AU
dc.contributor.authorZahra, Den_AU
dc.contributor.authorBourgeat, Pen_AU
dc.contributor.authorBerghofer, PJen_AU
dc.contributor.authorTamayo, AOen_AU
dc.contributor.authorWimberley, CAen_AU
dc.contributor.authorGrégoire, MCen_AU
dc.contributor.authorSalvado, Oen_AU
dc.date.accessioned2010-07-30T04:18:18Zen_AU
dc.date.available2010-07-30T04:18:18Zen_AU
dc.date.issued2010-02-14en_AU
dc.date.statistics2010-03en_AU
dc.description.abstractMicro-CT/PET imaging scanner provides a powerful tool to study tumor in small rodents in response to therapy. Accurate image registration is a necessary step to quantify the characteristics of images acquired in longitudinal studies. Small animal registration is challenging because of the very deformable body of the animal often resulting in different postures despite physical restraints. In this paper, we propose a non-rigid registration approach for the automatic registration of mouse whole body skeletons, which is based on our improved 3D shape context non-rigid registration method. The whole body skeleton registration approach has been tested on 21 pairs of mouse CT images with variations of individuals and time-instances. The experimental results demonstrated the stability and accuracy of the proposed method for automatic mouse whole body skeleton registration. © 2012, SPIE.en_AU
dc.identifier.booktitleMedical Imaging 2010: Biomedical Applications in Molecular, Structural, and Functional Imagingen_AU
dc.identifier.citationXiao, D., Zahra, D., Bourgeat, P., Berghofer, P., Tamayo, A. O., Wimberley, C., Grégoire, M. C., & Salvado. O. (2010). Non-rigid registration method for mouse whole body skeleton registration. Paper presented to the Medical Imaging 2010: Biomedical Applications in Molecular, Structural, and Functional Imaging, 14th February 2010. Town and Country Resort and Convention Center: San Diego, California. In Proceedings of SPIE, 7626, 76261N. doi:10.1117/12.844067en_AU
dc.identifier.conferenceenddate18 February 2010en_AU
dc.identifier.conferencenameMedical Imaging 2010: Biomedical Applications in Molecular, Structural, and Functional Imagingen_AU
dc.identifier.conferenceplaceSan Diego, Californiaen_AU
dc.identifier.conferencestartdate13 February 2010en_AU
dc.identifier.govdoc2082en_AU
dc.identifier.issn1605-7422en_AU
dc.identifier.pagination76261Nen_AU
dc.identifier.urihttp://dx.doi.org/10.1117/12.844067en_AU
dc.identifier.urihttp://apo.ansto.gov.au/dspace/handle/10238/1961en_AU
dc.identifier.volume7626en_AU
dc.language.isoenen_AU
dc.publisherSociety of Photo-optical Instrumentation Engineers (SPIE)en_AU
dc.subjectPositron computed tomographyen_AU
dc.subjectMiceen_AU
dc.subjectSkeletonen_AU
dc.subjectNeoplasmsen_AU
dc.subjectRestraintsen_AU
dc.subjectPositioningen_AU
dc.titleNon-rigid registration method for mouse whole body skeleton registration.en_AU
dc.typeConference Paperen_AU
Files
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: