Calculated K, L, and M shell X-ray line intensities for light ion impact on selected targets from Z=6 to 100
dc.contributor.author | Crawford, J | en_AU |
dc.contributor.author | Cohen, DD | en_AU |
dc.contributor.author | Doherty, G | en_AU |
dc.contributor.author | Atanacio, AJ | en_AU |
dc.date.accessioned | 2011-11-28T23:03:02Z | en_AU |
dc.date.available | 2011-11-28T23:03:02Z | en_AU |
dc.date.issued | 2011-09-01 | en_AU |
dc.date.statistics | 2011-11-29 | en_AU |
dc.description.abstract | A computer code to calculate the K, L, and M α, β and γ X-ray line intensities, KLMabgRatios, is described together with the input tables used to calculate these intensities for light ion bombardment of targets with atomic numbers from Z=6 to 100. The KLMabgRatios program was written with the main aim of updating the 1980’s data files used up till now (Clayton AAEC M113/1986), with more recent experimental and theoretical datasets published in the last 2 years or so. Preferred recommended K, L and M X-ray line intensities for light ion impact on selected targets for atomic numbers between Z=6 and 100 are given for 8 K lines, 17 L lines and 22 M lines as well as their corresponding ωK, ωL and ωM total shell fluorescence yields. In addition a program, wexplore, has been written to carry out Gaussian fits to experimental K, L and M X-ray spectra to better determine L and M X-ray production subshell cross sections for light ion bombardment. A section on the use of this wexplore program is also included in this report. | en_AU |
dc.identifier.citation | Crawford, J., Cohen, D., Doherty, G., & Atanacio, A. (2011). Calculated k, l and m-shell x-ray line intensities for light ion impact on selected targets from z=6 to 100 (ANSTO/E774). Lucas Heights, NSW: Australian Nuclear Science and Technology Organisation. | en_AU |
dc.identifier.govdoc | 3771 | en_AU |
dc.identifier.isbn | 1921268131 | en_AU |
dc.identifier.issn | 1030-7745 | en_AU |
dc.identifier.placeofpublication | Lucas Heights, New South Wales | en_AU |
dc.identifier.uri | http://apo.ansto.gov.au/dspace/handle/10238/3892 | en_AU |
dc.language.iso | en | en_AU |
dc.publisher | Australian Nuclear Science and Technology Organisation | en_AU |
dc.relation.ispartofseries | ANSTO External Reports; | en_AU |
dc.relation.ispartofseries | ANSTO-E-774; | en_AU |
dc.subject | Atomic number | en_AU |
dc.subject | Light ions | en_AU |
dc.subject | Computer calculations | en_AU |
dc.subject | X radiation | en_AU |
dc.subject | PIXE analysis | en_AU |
dc.subject | Fluorescence | en_AU |
dc.title | Calculated K, L, and M shell X-ray line intensities for light ion impact on selected targets from Z=6 to 100 | en_AU |
dc.type | External Report | en_AU |