Influence of rejection of a fraction of the single photoelectron peak in liquid scintillation counting
dc.contributor.author | Mo, L | en_AU |
dc.contributor.author | Cassette, P | en_AU |
dc.contributor.author | Baldock, C | en_AU |
dc.date.accessioned | 2010-08-24T01:43:34Z | en_AU |
dc.date.available | 2010-08-24T01:43:34Z | en_AU |
dc.date.issued | 2006-03-15 | en_AU |
dc.date.statistics | 2006-03-15 | en_AU |
dc.description.abstract | Zero discrimination level setting of liquid scintillation systems for counting of all single photoelectron pulses is required by both triple-to-double coincidence ratio (TDCR) and CIEMAT/NIST methods. However, this requirement may not be able to be met in some circumstances. The influence of rejection of a fraction of the single photoelectron peak has been studied both theoretically and experimentally on 3H, 63Ni, 14C and 90Sr/90Y for both the TDCR and CIEMAT/NIST methods. A modified formula for calculation of efficiency is given in consideration of the rejected fraction of the single photoelectron peak. © 2006, Elsevier Ltd. | en_AU |
dc.identifier.citation | Mo, L., Cassette, P., & Baldock, C. (2006). Influence of rejection of a fraction of the single photoelectron peak in liquid scintillation counting. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 558(2), 490-496. doi:10.1016/j.nima.2005.11.210 | en_AU |
dc.identifier.govdoc | 2526 | en_AU |
dc.identifier.issn | 0168-9002 | en_AU |
dc.identifier.issue | 2 | en_AU |
dc.identifier.journaltitle | Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment | en_AU |
dc.identifier.pagination | 490-496 | en_AU |
dc.identifier.uri | http://dx.doi.org/10.1016/j.nima.2005.11.210 | en_AU |
dc.identifier.uri | http://apo.ansto.gov.au/dspace/handle/10238/2326 | en_AU |
dc.identifier.volume | 558 | en_AU |
dc.language.iso | en | en_AU |
dc.publisher | Elsevier | en_AU |
dc.subject | Photoelectron counting | en_AU |
dc.subject | Fractionation | en_AU |
dc.subject | Liquid scintillation detectors | en_AU |
dc.subject | Coincidence methods | en_AU |
dc.subject | Peaks | en_AU |
dc.subject | Pulses | en_AU |
dc.title | Influence of rejection of a fraction of the single photoelectron peak in liquid scintillation counting | en_AU |
dc.type | Journal Article | en_AU |
Files
License bundle
1 - 1 of 1
Loading...
- Name:
- license.txt
- Size:
- 1.71 KB
- Format:
- Item-specific license agreed upon to submission
- Description: