Results of pipe bend analysis, Part IV: flexibility factors of pipe bends with flanged tangents

Loading...
Thumbnail Image
Date
1982-12
Journal Title
Journal ISSN
Volume Title
Publisher
Australian Atomic Energy Commission
Abstract
An equivalent flexibility factor is defined for pipe bends with flanged tangent pipes under pure in-plane bending, and numerical values of this factor are presented for a range of 90o and 180o bends with various tangent lengths.
Description
Keywords
Analytical solution, Bending, Flanges, Spatial distribution, Eigenvalues, Flexibility
Citation
Whatham, J. F. (1982). Results of pipe bend analysis, Part IV: flexibility factors of pipe bends with flanged tangents. (AAEC/E554). Lucas Heights, NSW: Australian Atomic Energy Commission.