Acoustic emission monitoring of a steam receiver pressurised to failure.

dc.contributor.authorBrown, KRen_AU
dc.contributor.authorHarris, RWen_AU
dc.contributor.authorWood, BRAen_AU
dc.date.accessioned2007-11-22T04:27:24Zen_AU
dc.date.accessioned2010-04-30T04:38:20Zen_AU
dc.date.available2007-11-22T04:27:24Zen_AU
dc.date.available2010-04-30T04:38:20Zen_AU
dc.date.issued1978-04en_AU
dc.description.abstractAustralian Atomic Energy Commission and the Australian Welding Research Association have conducted acoustic emission monitoring of a large defective pressure vessel during pressurisation to failure. Using acoustic emission source location equipment, it was possible to locate, in real time, areas of high activity. Later, fractographic examination of the failed vessel indicated that failure had initiated at the area of highest activity and this area was identified well before failure occurred.en_AU
dc.identifier.citationBrown, K., Harris, R., & Wood, B. (1978). Acoustic emission monitoring of a steam receiver pressurised to failure (AAEC/E447). Lucas Heights, N.S.W.: Research Establishment, Australian Atomic Energy Commission.en_AU
dc.identifier.govdoc672en_AU
dc.identifier.isbn0642596484en_AU
dc.identifier.otherAAEC-E-447en_AU
dc.identifier.placeofpublicationLucas Heights, New South Walesen_AU
dc.identifier.urihttp://apo.ansto.gov.au/dspace/handle/10238/662en_AU
dc.language.isoen_auen_AU
dc.publisherAustralian Atomic Energy Commissionen_AU
dc.subjectAcousticsen_AU
dc.subjectAcoustic emission testingen_AU
dc.subjectPressure vesselsen_AU
dc.subjectFailuresen_AU
dc.titleAcoustic emission monitoring of a steam receiver pressurised to failure.en_AU