Post treatment dose distribution evaluation for a recent NCT patient

dc.contributor.authorStorr, GJen_AU
dc.contributor.authorWheeler, FJen_AU
dc.date.accessioned2026-01-06T04:56:39Zen_AU
dc.date.available2026-01-06T04:56:39Zen_AU
dc.date.issued1993en_AU
dc.date.statistics2025-12-16en_AU
dc.descriptionPhysical copy held by ANSTO Library at DDC:616.9940642/3en_AU
dc.description.abstractAs a prelude to establishing, (1) criteria for selection of Boron Neutron Capture Therapy (BNCT) epithermal beam clinical trial patients and (2) treatment planning strategies, post-treatment evaluations of dose distributions in several BNCT patients are being done using the Idaho National Engineering Laboratory (INEL) BNCT Program's patient treatment planning software (bnct-edit and rtt-MC). The objectives of this work are: (i) calculate the dose delivered to the BNCT treated patients (ii) calculate the possible dose distribution for the patients using the proposed Georgia Institute of Technology's reactor epithermal beam (iii) correlate calculated dose with effect © Plenum Pressen_AU
dc.identifier.booktitleAdvances in Capture Therapy for Canceren_AU
dc.identifier.citationStorr, G. J., & Wheeler, F. J. (1993). Post treatment dose distribution evaluation for a recent NCT patient. Paper presented to the Fifth International Symposium on Neutron Capture Therapy for Cancer, September 13-17, Columbus, Ohio, USA. In Soloway, A. H., Barth, R. F., Carpenter, D. E. (eds) Advances in Neutron Capture Therapy, (pp. 153-157). Boston, MA : Plenum Press.en_AU
dc.identifier.conferenceenddate1992-09-17en_AU
dc.identifier.conferencenameFifth International Symposium on Neutron Capture Therapy for Canceren_AU
dc.identifier.conferenceplaceColumbus, Ohioen_AU
dc.identifier.conferencestartdate1992-09-13en_AU
dc.identifier.editorsSoloway, A. H., Barth, R. F., & Carpenter, D. E.en_AU
dc.identifier.isbn0306445670en_AU
dc.identifier.pagination153-157en_AU
dc.identifier.placeofpublicationNew York, USAen_AU
dc.identifier.urihttps://apo.ansto.gov.au/handle/10238/16835en_AU
dc.language.isoenen_AU
dc.publisherPlenum Pressen_AU
dc.subjectB Codesen_AU
dc.subjectComputer codesen_AU
dc.subjectNeutron capture therapyen_AU
dc.subjectPatientsen_AU
dc.subjectR codesen_AU
dc.subjectSpatial dose distributionsen_AU
dc.subjectRadiotherapyen_AU
dc.subjectTherapyen_AU
dc.titlePost treatment dose distribution evaluation for a recent NCT patienten_AU
dc.typeConference Paperen_AU
Files
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.63 KB
Format:
Item-specific license agreed upon to submission
Description: