Post treatment dose distribution evaluation for a recent NCT patient

No Thumbnail Available
Date
1993
Journal Title
Journal ISSN
Volume Title
Publisher
Plenum Press
Abstract
As a prelude to establishing, (1) criteria for selection of Boron Neutron Capture Therapy (BNCT) epithermal beam clinical trial patients and (2) treatment planning strategies, post-treatment evaluations of dose distributions in several BNCT patients are being done using the Idaho National Engineering Laboratory (INEL) BNCT Program's patient treatment planning software (bnct-edit and rtt-MC). The objectives of this work are: (i) calculate the dose delivered to the BNCT treated patients (ii) calculate the possible dose distribution for the patients using the proposed Georgia Institute of Technology's reactor epithermal beam (iii) correlate calculated dose with effect © Plenum Press
Description
Physical copy held by ANSTO Library at DDC:616.9940642/3
Keywords
B Codes, Computer codes, Neutron capture therapy, Patients, R codes, Spatial dose distributions, Radiotherapy, Therapy
Citation
Storr, G. J., & Wheeler, F. J. (1993). Post treatment dose distribution evaluation for a recent NCT patient. Paper presented to the Fifth International Symposium on Neutron Capture Therapy for Cancer, September 13-17, Columbus, Ohio, USA. In Soloway, A. H., Barth, R. F., Carpenter, D. E. (eds) Advances in Neutron Capture Therapy, (pp. 153-157). Boston, MA : Plenum Press.