Please use this identifier to cite or link to this item:
https://apo.ansto.gov.au/dspace/handle/10238/798
Title: | Relative holdup of heat exchanges for circulating fuel systems. |
Authors: | Sodium Berglin, CLW |
Keywords: | Heat exchangers Fuel systems Uranium Bismuth |
Issue Date: | Jun-1958 |
Publisher: | Australian Atomic Energy Commission |
Citation: | Berglin, C. L. W. (1958). Relative holdup of heat exchangers for circulating fuel systems AAEC/E1). Lucas Heights, N.S.W.: Research Establishment, Australian Atomic Energy Commission. |
Abstract: | This report sets out the relative holdup for tube type heat exchangers of sodium-uranium suspension and bismuth-uranium solution systems for various sizes of tube and tube wall thickness. It shows that based on a temperature difference of 50ºc the holdup in the heat exchanger for the sodium-uranium suspension is at least 6 times that for the bismuth-uranium solution and as a conservative estimate may be taken as 8 times. A table is included of the leading dimensions of heat exchangers or a heat load of 500 MW with tubes of 3/4" and 1" outside diameter respectively. |
Gov't Doc #: | 808 |
URI: | http://apo.ansto.gov.au/dspace/handle/10238/798 |
Appears in Collections: | Scientific and Technical Reports |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
AAEC-E-1.pdf | 830.12 kB | Adobe PDF | ![]() View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.