Relative holdup of heat exchanges for circulating fuel systems.
Loading...
Files
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Australian Atomic Energy Commission
Abstract
This report sets out the relative holdup for tube type heat exchangers of sodium-uranium suspension and bismuth-uranium solution systems for various sizes of tube and tube wall thickness. It shows that based on a temperature difference of 50ºc the holdup in the heat exchanger for the sodium-uranium suspension is at least 6 times that for the bismuth-uranium solution and as a conservative estimate may be taken as 8 times. A table is included of the leading dimensions of heat exchangers or a heat load of 500 MW with tubes of 3/4" and 1" outside diameter respectively.
Description
Keywords
Citation
Berglin, C. L. W. (1958). Relative holdup of heat exchangers for circulating fuel systems AAEC/E1). Lucas Heights, N.S.W.: Research Establishment, Australian Atomic Energy Commission.