Repository logo


Coincidence-counting corrections for accidental coincidences, set dead time and intrinsic dead time

Loading...
Thumbnail Image

Journal Title

Journal ISSN

Volume Title

Publisher

Australian Nuclear Science and Technology Organisation

Abstract

An equation is derived for calculating the radioactivity of a source from the results of coincidence counting taking into account dead-time losses and accidental coincidences. The corrections allow for the extension of the set dead time in the β channel by the intrinsic dead time. Experimental verification shows improvement over a previous equation.

Description

Citation

Wyllie, H. A. (1987). Coincidence-counting corrections for accidental coincidences, set dead time and intrinsic dead time (ANSTO-E-700). Lucas Heights, NSW: Australian Nuclear Science and Technology Organisation.

Endorsement

Review

Supplemented By

Referenced By