Repository logo


Suggestions for work on design of heat exchangers in liquid metal fueled reactors

Loading...
Thumbnail Image

Journal Title

Journal ISSN

Volume Title

Publisher

Australian Atomic Energy Commission

Abstract

The report discusses the low heat transfer film coefficient on the secondary coolant side of tubular exchangers used in the calculations in AAEC-E-1. It suggests the types of heat exchangers which should be investigated in order to improve this coefficient and in turn to reduce the relative hold-up.

Description

Citation

Berglin, C. L. W. (1956). Suggestions for work on design of heat exchangers in liquid metal fuelled reactors (AAEC/E2). Lucas Heights, N.S.W.: Research Establishment, Australian Atomic Energy Commission.