Suggestions for work on design of heat exchangers in liquid metal fueled reactors

dc.contributor.authorBerglin, CLWen_AU
dc.date.accessioned2007-11-22T04:20:49Zen_AU
dc.date.accessioned2010-04-30T04:30:16Zen_AU
dc.date.available2007-11-22T04:20:49Zen_AU
dc.date.available2010-04-30T04:30:16Zen_AU
dc.date.issued1956-06en_AU
dc.description.abstractThe report discusses the low heat transfer film coefficient on the secondary coolant side of tubular exchangers used in the calculations in AAEC-E-1. It suggests the types of heat exchangers which should be investigated in order to improve this coefficient and in turn to reduce the relative hold-up.en_AU
dc.identifier.citationBerglin, C. L. W. (1956). Suggestions for work on design of heat exchangers in liquid metal fuelled reactors (AAEC/E2). Lucas Heights, N.S.W.: Research Establishment, Australian Atomic Energy Commission.en_AU
dc.identifier.govdoc211en_AU
dc.identifier.otherAAEC-E-2en_AU
dc.identifier.placeofpublicationLucas Heights, New South Walesen_AU
dc.identifier.urihttp://apo.ansto.gov.au/dspace/handle/10238/384en_AU
dc.language.isoen_auen_AU
dc.publisherAustralian Atomic Energy Commissionen_AU
dc.subjectHeat exchangersen_AU
dc.subjectCoolantsen_AU
dc.subjectLiquid metal fuelsen_AU
dc.subjectLiquid metal cooled reactorsen_AU
dc.titleSuggestions for work on design of heat exchangers in liquid metal fueled reactorsen_AU
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
AAEC-E-2.pdf
Size:
94.44 KB
Format:
Adobe Portable Document Format
Description: