Please use this identifier to cite or link to this item:
https://apo.ansto.gov.au/dspace/handle/10238/177| Title: | Impermeable graphite as a fuel can, Part 2 - apparatus for the measurement of permeability. |
| Authors: | Wall, GC |
| Keywords: | Tracer techniques Radiopharmaceuticals Fuel cans Graphite Permeability |
| Issue Date: | Aug-1961 |
| Publisher: | Australian Atomic Energy Commission |
| Citation: | Wall, G. C. (1961). Impermeable graphite as a fuel can, Part 2 - apparatus for the measurement of permeability. Lucas Heights, NSW: Australian Atomic Energy Commission. |
| Abstract: | An apparatus is described which is capable of measuring permeabilities of porous media down to 4x10-11 cm2 sec-1 with a maximum error of ten per cent. The method, which uses a radioactive tracer technique, eliminates the errors due to gas leakage which are inherent in conventional apparatus for permeability measurement. |
| Gov't Doc #: | 326 |
| URI: | http://apo.ansto.gov.au/dspace/handle/10238/177 |
| Appears in Collections: | Scientific and Technical Reports |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| AAEC-E-73.pdf | 327.96 kB | Adobe PDF | ![]() View/Open |