Impermeable graphite as a fuel can, Part 2 - apparatus for the measurement of permeability.

dc.contributor.authorWall, GCen_AU
dc.date.accessioned2007-11-22T04:14:10Zen_AU
dc.date.accessioned2010-04-30T04:32:08Zen_AU
dc.date.available2007-11-22T04:14:10Zen_AU
dc.date.available2010-04-30T04:32:08Zen_AU
dc.date.issued1961-08en_AU
dc.description.abstractAn apparatus is described which is capable of measuring permeabilities of porous media down to 4x10-11 cm2 sec-1 with a maximum error of ten per cent. The method, which uses a radioactive tracer technique, eliminates the errors due to gas leakage which are inherent in conventional apparatus for permeability measurement.en_AU
dc.identifier.citationWall, G. C. (1961). Impermeable graphite as a fuel can, Part 2 - apparatus for the measurement of permeability. Lucas Heights, NSW: Australian Atomic Energy Commission.en_AU
dc.identifier.govdoc326en_AU
dc.identifier.otherAAEC-E-73en_AU
dc.identifier.urihttp://apo.ansto.gov.au/dspace/handle/10238/177en_AU
dc.language.isoen_auen_AU
dc.publisherAustralian Atomic Energy Commissionen_AU
dc.subjectTracer techniquesen_AU
dc.subjectRadiopharmaceuticalsen_AU
dc.subjectFuel cansen_AU
dc.subjectGraphiteen_AU
dc.subjectPermeabilityen_AU
dc.titleImpermeable graphite as a fuel can, Part 2 - apparatus for the measurement of permeability.en_AU