The imaging and medical beamline is expanding

dc.contributor.authorHäusermann, Den_AU
dc.contributor.authorMcKinlay, Jen_AU
dc.contributor.authorMorey, Cen_AU
dc.contributor.authorPelliccia, Den_AU
dc.date.accessioned2023-04-28T06:24:24Zen_AU
dc.date.available2023-04-28T06:24:24Zen_AU
dc.date.issued2021-11-24en_AU
dc.date.statistics2023-04-21en_AU
dc.description.abstractSynchrotron radiation has many advantages, but it is also flawed. And its biggest flaw happens to be its fundamental intrinsic property! The radiation is emitted in the plane of the stored beam and we are stuck with the infamous ‘letterbox door’ beam profile. At least when not tinkering with focused undulator beams. In clinical imaging research, this beam shape is a serious disadvantage. In fact, when compared with the field of view of commercial medical imaging devices, it is often the showstopper when engaging with a clinician to discuss medical application of the IMBL. So how will we image human patients in 2022, as part of our world leading research project in breast CT imaging and cancer detection? Our vertical ‘letter box opening’ at 135 meter is 3 cm, at 35 keV, with a roll off of 50%. This is far from ideal for imaging the breasts of a patient lying in a prone position on our robotic positioning and scanning stage. Consequently, we have designed and tested a Bragg-Bragg beam expander to be placed downstream of our double-bent-Laue primary monochromator. The net result is an 8 cm vertical beam profile at 135 meter, with minimal roll off, to match the vertical field of view of our new EIGER2 CdTe X 3M clinical detector. This paper will present the design of our beam expander and the results of our in-air tests. This device will be installed in vacuum in the next machine shutdown. © 2021 The Authorsen_AU
dc.description.sponsorshipAnna Sokolova is attached to this item in the program. However, she is not listed as an Author on the presentation.en_AU
dc.identifier.citationHausermann, D., McKinlay, J., Morey, C., & Pelliccia, D. (2021). The imaging and medical beamline is expanding. Presentation to the ANSTO User Meeting, Online, 24-26 November 2021. Retrieved from: https://events01.synchrotron.org.au/event/146/contributions/4314/contribution.pdfen_AU
dc.identifier.conferenceenddate26 November 2021en_AU
dc.identifier.conferencenameANSTO User Meeting 2021en_AU
dc.identifier.conferenceplaceOnlineen_AU
dc.identifier.conferencestartdate24 November 2021en_AU
dc.identifier.urihttps://events01.synchrotron.org.au/event/146/contributions/4314/contribution.pdfen_AU
dc.identifier.urihttps://apo.ansto.gov.au/dspace/handle/10238/14946en_AU
dc.language.isoenen_AU
dc.publisherAustralian Nuclear Science and Technology Organisationen_AU
dc.subjectBeamsen_AU
dc.subjectSynchrotron radiationen_AU
dc.subjectWiggler magnetsen_AU
dc.subjectImagesen_AU
dc.subjectNeoplasmsen_AU
dc.subjectMammary glandsen_AU
dc.subjectCAT scanningen_AU
dc.titleThe imaging and medical beamline is expandingen_AU
dc.typeConference Presentationen_AU
Files
Original bundle
Now showing 1 - 2 of 2
Loading...
Thumbnail Image
Name:
contribution-19.pdf
Size:
362.14 KB
Format:
Adobe Portable Document Format
Description:
Loading...
Thumbnail Image
Name:
OgrEWivv_926509.pdf
Size:
1.43 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.63 KB
Format:
Item-specific license agreed upon to submission
Description: