High‐resolution triple‐crystal x‐ray‐diffraction experiments performed at the Australian National Beamline Facility in Japan

dc.contributor.authorNikulin, AYen_AU
dc.contributor.authorStevenson, AWen_AU
dc.contributor.authorHashizume, Hen_AU
dc.contributor.authorWilkins. SWen_AU
dc.contributor.authorCookson, DJen_AU
dc.contributor.authorForan, Gen_AU
dc.contributor.authorGarrett, RFen_AU
dc.date.accessioned2024-05-07T23:55:29Zen_AU
dc.date.available2024-05-07T23:55:29Zen_AU
dc.date.issued1994-07-18en_AU
dc.date.statistics2024-04-23en_AU
dc.descriptionPhysical copy held by ANSTO Library at DDC: 539.735/22. Also available online at: https://doi.org/10.1063/1.1145947.en_AU
dc.description.abstractThe x‐ray‐diffraction results reported here are from the first high‐resolution triple‐crystal experiments to be performed at the Australian National Beamline Facility at the Photon Factory. The heart of the facility is a multipurpose two‐axis high‐resolution vacuum diffractometer (BIGDIFF) Z. Barnea et al., Rev. Sci. Instrum. 63, 1069 (1992) capable of use for high‐resolution powder diffraction (using both conventional scintillation detectors and imaging plates), protein crystallography, reflectometry, as well as single‐crystal diffractometry. The present experiments were conducted on BIGDIFF in triple‐crystal diffraction mode with a monolithic channel‐cut Si monochromator (supplied by Professor M. Hart), a single‐crystal Si sample, and a four‐reflection monolithic channel‐cut Si analyzer crystal. The Si(111) sample is a part of a wafer which had been implanted with 100 keV B+ ions (doses 1×1015 and 5×1015 cm−2) through a one‐dimensional 0.5 μm thick oxide strip pattern with a 5.83 μm period and 4 μm open region. The triple‐crystal data were collected in the form of two‐dimensional intensity maps in the vicinity of the 111 Bragg peak, varying the sample rotation (ω) and the analyzer/scintillation detector rotation (2θ). The first results were collected in air both with the as‐described sample and after the oxide layer had been removed. Certain slice scans (one‐dimensional sections of the two‐dimensional intensity maps) were also collected with a vacuum of 1 Torr and reveal considerable improvement in signal to background. The data will be compared with a recent similar study A. Yu. Nikulin et al., J. Appl. Cryst. 27, 338 (1994) performed on BL‐14B at the Photon Factory. The new data collected in air indicate that lattice distortion may be mapped with a resolution of approximately 160 Å, to a depth of approximately 1.0 μm, providing valuable quantitative information on ion diffusion in such implanted materials. The slice scans collected in vacuum indicate that a depth resolution of 50 Å is certainly achievable using BIGDIFF. The data show the excellent potential of BIGDIFF for extremely good signal to noise and very high resolution in such experiments, and the advantages of working entirely in vacuum. © 1995 American Institute of Physics.en_AU
dc.identifier.booktitleProceedings of the 5th International Conference on Synchrotron Radiation Instrumentation : Stony Brook, New York, 18-22 July 1994en_AU
dc.identifier.citationNikulin, A. Y., Stevenson, A. W., Hashizume, H., Wilkins, S. W., Cookson, D., Foran, G., & Garrett, R. F. (1995). High‐resolution triple‐crystal x‐ray‐diffraction experiments performed at the Australian National Beamline Facility in Japan. Presentation to the 5th International Conference on Synchrotron Radiation Instrumentation, Stony Brook, New York, 18-22 July 1994. In J. B. Hasting, S. L Hulbert,, & G. P Williams (eds), Proceedings of the 5th International Conference on Synchrotron Radiation Instrumentation, 18−22 July 1994, Stony Brook, New York (USA), Vol. 66(2), pp. 1483.en_AU
dc.identifier.conferenceenddate1994-02-22en_AU
dc.identifier.conferencename5th International Conference on Synchrotron Radiation Instrumentationen_AU
dc.identifier.conferenceplaceStony, Brook, New Yorken_AU
dc.identifier.conferencestartdate1994-07-18en_AU
dc.identifier.editorsHastings. J. B., Hulbert, S. L. Williams. G. P.en_AU
dc.identifier.isbn156396452Xen_AU
dc.identifier.issn1089-7623en_AU
dc.identifier.issn0034-6748en_AU
dc.identifier.issue2en_AU
dc.identifier.pagination1483en_AU
dc.identifier.placeofpublicationUnited States of Americaen_AU
dc.identifier.urihttps://apo.ansto.gov.au/handle/10238/15587en_AU
dc.identifier.volume66en_AU
dc.language.isoenen_AU
dc.publisherAmerican Institute of Physicsen_AU
dc.relation.urihttps://doi.org/10.1063/1.1145947en_AU
dc.subjectCrystalsen_AU
dc.subjectDiffractionen_AU
dc.subjectBeamsen_AU
dc.subjectJapanese organizationsen_AU
dc.subjectBragg curveen_AU
dc.subjectScintillationsen_AU
dc.subjectResolutionen_AU
dc.titleHigh‐resolution triple‐crystal x‐ray‐diffraction experiments performed at the Australian National Beamline Facility in Japanen_AU
dc.typeConference Abstracten_AU
Files
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.63 KB
Format:
Item-specific license agreed upon to submission
Description: