Optimising parameters for meaningful measurement of residual strain by neutron diffraction in self-pierce riveted joints

dc.contributor.authorHaque, Ren_AU
dc.contributor.authorDurandet, Yen_AU
dc.contributor.authorWong, YCen_AU
dc.contributor.authorParadowska, AMen_AU
dc.contributor.authorBeynon, JHen_AU
dc.contributor.authorBlacket, Sen_AU
dc.date.accessioned2013-10-10T04:40:35Zen_AU
dc.date.available2013-10-10T04:40:35Zen_AU
dc.date.issued2013-11-18en_AU
dc.date.statistics2013-10-10en_AU
dc.description.abstractThe aim of this work is to examine the uncertainties involved in measuring residual strain and their dependence on both the gauge volume of the neutron beam and the acquisition time in self pierce riveted (SPR) joints while using the neutron diffraction technique. The main challenge involved dealing with the very small dimensions of SPR joints and developing optimum instrument configuration that allowed faster and/or more accurate stress measurement in SPR while maintaining the same time resolution required for the millimetre scale of the problem. Two different gauge volumes were used (0.125 and 1.0 mm(3)), and two different measuring directions were chosen in order to examine the rotational accuracy of the sample table. All measurements were conducted in steel–steel joints. Even though small sizes were involved, meaningful results were obtained and measurement errors were reduced by optimising the instrument parameters. © 2013, Maney Publishingen_AU
dc.identifier.citationHaque, R., Durandet, Y., Wong, Y. C., Paradowska, A., Beynon, J. H., & Blacket, S. (2013). Optimising parameters for meaningful measurement of residual strain by neutron diffraction in self-pierce riveted joints. Science and Technology of Welding and Joining, 18, 492-499. doi:10.1179/1362171813y.0000000126en_AU
dc.identifier.govdoc5091en_AU
dc.identifier.issn1362-1718en_AU
dc.identifier.journaltitleScience and Technology of Welding and Joiningen_AU
dc.identifier.pagination492-499en_AU
dc.identifier.urihttp://dx.doi.org/10.1179/1362171813y.0000000126en_AU
dc.identifier.urihttp://apo.ansto.gov.au/dspace/handle/10238/4784en_AU
dc.identifier.volume18en_AU
dc.language.isoenen_AU
dc.publisherManey Publishingen_AU
dc.subjectJoiningen_AU
dc.subjectNeutron diffractionen_AU
dc.subjectNeutron beamsen_AU
dc.subjectDiesen_AU
dc.subjectSteelsen_AU
dc.subjectVolumeen_AU
dc.titleOptimising parameters for meaningful measurement of residual strain by neutron diffraction in self-pierce riveted jointsen_AU
dc.typeJournal Articleen_AU
Files
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description:
Collections