First experiments on the Australian Synchrotron imaging and medical beamline, including investigations of the effective source size in respect of x-ray imaging

dc.contributor.authorStevenson, AWen_AU
dc.contributor.authorMayo, SCen_AU
dc.contributor.authorHäusermann, Den_AU
dc.contributor.authorMaksimenko, Aen_AU
dc.contributor.authorGarrett, RFen_AU
dc.contributor.authorHall, CJen_AU
dc.contributor.authorWilkins, SWen_AU
dc.contributor.authorLewis, RAen_AU
dc.contributor.authorMyers, DEen_AU
dc.date.accessioned2010-01-20T04:02:31Zen_AU
dc.date.accessioned2010-04-30T05:07:41Zen_AU
dc.date.available2010-01-20T04:02:31Zen_AU
dc.date.available2010-04-30T05:07:41Zen_AU
dc.date.issued2010-01en_AU
dc.date.statistics2010-01en_AU
dc.description.abstractThe Imaging and Medical beamline at the Australian Synchrotron achieved 'first light' in December 2008. Here, the first experiments performed on the beamline are reported, which involved both X-ray imaging and tomography studies for a range of samples. The use of a plastic-edge phantom for quantitative measurements of contrast and resolution proved to be very instructive and helped to confirm certain parameter values such as the effective horizontal source size, detector resolution and average X-ray energy for the polychromatic beam. © 2010, International Union of Crystallographyen_AU
dc.identifier.citationStevenson, A. W., Mayo, S. C., Hausermann, D., Maksimenko, A., Garrett, R. F., & Hall, C. J., Wilkins, S. W., Lewis, R. A., Myers, D. E. (2010). First experiments on the Australian Synchrotron imaging and medical beamline, including investigations of the effective source size in respect of x-ray imaging. Journal of Synchrotron Radiation, 17, 75-80. doi:10.1107/S0909049509041788en_AU
dc.identifier.govdoc1494en_AU
dc.identifier.issn0909-0495en_AU
dc.identifier.journaltitleJournal of Synchrotron Radiationen_AU
dc.identifier.pagination75-80en_AU
dc.identifier.urihttp://dx.doi.org/10.1107/S0909049509041788en_AU
dc.identifier.urihttp://apo.ansto.gov.au/dspace/handle/10238/2711en_AU
dc.identifier.volume17en_AU
dc.language.isoenen_AU
dc.publisherInternational Union of Crystallographyen_AU
dc.subjectSynchrotronsen_AU
dc.subjectX-ray sourcesen_AU
dc.subjectTomographyen_AU
dc.subjectAustraliaen_AU
dc.subjectRadiationsen_AU
dc.subjectImagesen_AU
dc.titleFirst experiments on the Australian Synchrotron imaging and medical beamline, including investigations of the effective source size in respect of x-ray imagingen_AU
dc.typeJournal Articleen_AU
Files
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.8 KB
Format:
Plain Text
Description:
Collections