Localisation of trace metals in metal-accumulating plants using μ-PIXE
dc.contributor.author | Siegele, R | en_AU |
dc.contributor.author | Kachenko, AG | en_AU |
dc.contributor.author | Bhatia, NP | en_AU |
dc.contributor.author | Wang, YD | en_AU |
dc.contributor.author | Ionescu, M | en_AU |
dc.contributor.author | Singh, B | en_AU |
dc.contributor.author | Baker, AJM | en_AU |
dc.contributor.author | Cohen, DD | en_AU |
dc.date.accessioned | 2009-06-19T01:52:51Z | en_AU |
dc.date.accessioned | 2010-04-30T05:02:28Z | en_AU |
dc.date.available | 2009-06-19T01:52:51Z | en_AU |
dc.date.available | 2010-04-30T05:02:28Z | en_AU |
dc.date.issued | 2008-03 | en_AU |
dc.date.statistics | 2008-03 | en_AU |
dc.description.abstract | Particle induced x-ray emission (PIXE) is a very sensitive technique that can quickly and reliably measure a wide range of elements simultaneously with high sensitivity. Using a focused microbeam, elemental distributions can be mapped with high spatial resolution. We demonstrate high-resolution mapping of metals in plant leaves at 5 mu m resolution and its application in detecting sites of metal accumulation in metal-accumulating plant tissues. The importance of biological sample preparation is discussed by direct comparison of freeze-substitution and freeze-drying techniques routinely used in biological sciences. The advantages and limitations of quantitative elemental imaging using these techniques are also discussed. © 2008, Wiley-Blackwell. | en_AU |
dc.identifier.citation | Siegele, R., Kachenko, A. G., Bhatia, N. P., Wang, Y. D., Ionescu, M., Singh, B., Baker, A. J. M., & Cohen, D. D. (2008). Localisation of trace metals in metal-accumulating plants using μ-PIXE. X-Ray Spectrometry, 37(2), 133-136. doi:10.1002/xrs.1035 | en_AU |
dc.identifier.govdoc | 1153 | en_AU |
dc.identifier.issn | 0049-8246 | en_AU |
dc.identifier.issue | 2 | en_AU |
dc.identifier.journaltitle | X-Ray Spectrometry | en_AU |
dc.identifier.pagination | 133-136 | en_AU |
dc.identifier.uri | http://dx.doi.org/10.1002/xrs.1035 | en_AU |
dc.identifier.uri | http://apo.ansto.gov.au/dspace/handle/10238/1433 | en_AU |
dc.identifier.volume | 37 | en_AU |
dc.language.iso | en | en_AU |
dc.publisher | Wiley-Blackwell | en_AU |
dc.subject | PIXE analysis | en_AU |
dc.subject | Plants | en_AU |
dc.subject | Metals | en_AU |
dc.subject | Leaves | en_AU |
dc.subject | Plant tissues | en_AU |
dc.subject | Lyophilization | en_AU |
dc.title | Localisation of trace metals in metal-accumulating plants using μ-PIXE | en_AU |
dc.type | Journal Article | en_AU |
Files