Comparison of SOI microdosimeter and tissue equivalent proportional counter measurements at the CERF facility

dc.contributor.authorProkopovich, DAen_AU
dc.contributor.authorReinhard, MIen_AU
dc.contributor.authorTaylor, GCen_AU
dc.contributor.authorHands, Aen_AU
dc.contributor.authorRosenfeld, ABen_AU
dc.date.accessioned2010-08-06T06:52:48Zen_AU
dc.date.available2010-08-06T06:52:48Zen_AU
dc.date.issued2010-01-29en_AU
dc.date.statistics2010-01-29en_AU
dc.description.abstractThe CERN-EU High Energy Reference Field (CERF) facility is used in the calibration of neutron dosimeters for aviation and high energy physics applications. A comparison of the facility's microdosimetric spectra obtained with a new Silicon on Insulator (SOI) Microdosimeter and a HAWK Tissue Equivalent Proportional Counter (TEPC) are presented. Experimental measurements with a silicon PIN dosimeter diode are also described which indicate a small but significant contribution from charged particles to dosimetry measurements within the neutron dominated field.en_AU
dc.identifier.booktitleProceedings of the 2009 IEEE Nuclear Science Symposium and Medical Imaging Conferenceen_AU
dc.identifier.citationProkopovich, D. A, Reinhard, M. I., Taylor, G. C., Hands, A., & Rosenfeld, A. B. (2010). Comparison of SOI microdosimeter and tissue equivalent proportional counter measurements at the CERF facility. 2009 IEEE Nuclear Science Symposium and Medical Imaging Conference (2009 NSS/MIC), 25th – 31st October 2009. In Proceedings of the 2009 IEEE Nuclear Science Symposium and Medical Imaging Conference, (pp. 2351-2354). Orlando, Florida: Hilton Disney World Hotel. doi:10.1109/NSSMIC.2009.5402229en_AU
dc.identifier.conferenceenddate31 October 2009en_AU
dc.identifier.conferencename2009 IEEE Nuclear Science Symposium and Medical Imaging Conference (2009 NSS/MIC)en_AU
dc.identifier.conferenceplaceOrlando, Floridaen_AU
dc.identifier.conferencestartdate25 October 2009en_AU
dc.identifier.govdoc2241en_AU
dc.identifier.isbn9781424439614en_AU
dc.identifier.issn1082-3654en_AU
dc.identifier.pagination2351-2354en_AU
dc.identifier.urihttp://dx.doi.org/10.1109/NSSMIC.2009.5402229en_AU
dc.identifier.urihttp://apo.ansto.gov.au/dspace/handle/10238/2103en_AU
dc.language.isoenen_AU
dc.publisherInstitute of Electrical and Electronics Engineers (IEEE)en_AU
dc.subjectMicrodosimetryen_AU
dc.subjectHigh energy physicsen_AU
dc.subjectSiliconen_AU
dc.subjectBragg Gray chambersen_AU
dc.subjectCERNen_AU
dc.subjectProportional countersen_AU
dc.titleComparison of SOI microdosimeter and tissue equivalent proportional counter measurements at the CERF facilityen_AU
dc.typeConference Paperen_AU
Files
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: