From imaging to dosimetry: GEANT4-based study on the application of medipix to neutron dosimetry

dc.contributor.authorOthman, MARen_AU
dc.contributor.authorMarinaro, DGen_AU
dc.contributor.authorPetasecca, Men_AU
dc.contributor.authorGuatelli, Sen_AU
dc.contributor.authorCutajar, DLen_AU
dc.contributor.authorLerch, MLFen_AU
dc.contributor.authorProkopovich, DAen_AU
dc.contributor.authorReinhard, MIen_AU
dc.contributor.authorUher, Jen_AU
dc.contributor.authorJakubek, Jen_AU
dc.contributor.authorPospisil, Sen_AU
dc.contributor.authorRosenfeld, ABen_AU
dc.date.accessioned2011-02-28T04:26:52Zen_AU
dc.date.available2011-02-28T04:26:52Zen_AU
dc.date.issued2009-10-12en_AU
dc.date.statistics2009-10-12en_AU
dc.description.abstractAn application of Medipix2 using a newly developed segmented multiple thickness polyethylene (PE) converter for fast neutron detection is presented. The system has the ability to provide an energy independent response for the dose equivalent for fast neutrons. The application of weighting factors to each defined thickness of PE allows for a flattening of the response of the detector system for dosimetry applications. Six PE converter segments were applied, and their thicknesses and weighting factors were optimised to obtain the required energy independent detector response. The study performed by means of GEANT4. Its suitability for neutron dosimetry was studied with respect to a previously published work. © 2013 Elsevier B.V.en_AU
dc.description.sponsorshipiThemba Laboratory for Accelerator-Based Sciences; National Research Foundation; European Radiation Dosimetry Group; South African Nuclear Energy Corporation; National Physical Laboratory (UK); Institut de Radioprotection et de Sûreté Nucléaire (France)en_AU
dc.identifier.citationOthman, M. A. R., Marinaro, D. G., Petasecca, M., Guatelli, S., Cutajar, D. L., Lerch, M. L. F., Prokopovich, D. A., Reinhard, M. I., Uher, J., Janubek, J., Pospisil, S., & Rosenfeld, A. B. (2009). From imaging to dosimetry: GEANT4-based study on the application of medipix to neutron dosimetry. Poster presented to the 11th Neutron and Ion Dosimetry Symposium (NEUDOS-11), 11th - 16th October 2009. iThemba Laboratory for Accelerator-Based Sciences: Cape Town, South Africa. In Radiation Measurements, 45(10), 1355-1358. doi:10.1016/j.radmeas.2010.06.058en_AU
dc.identifier.conferenceenddate16 October 2009en_AU
dc.identifier.conferencename11th Neutron and Ion Dosimetry Symposium (NEUDOS-11)en_AU
dc.identifier.conferenceplaceCape Town, South Africaen_AU
dc.identifier.conferencestartdate11 October 2009en_AU
dc.identifier.govdoc3231en_AU
dc.identifier.issn1350-4487en_AU
dc.identifier.issue10en_AU
dc.identifier.journaltitleRadiation Measurementsen_AU
dc.identifier.pagination1355-1358en_AU
dc.identifier.urihttp://dx.doi.org/10.1016/j.radmeas.2010.06.058en_AU
dc.identifier.urihttp://apo.ansto.gov.au/dspace/handle/10238/3098en_AU
dc.identifier.volume45en_AU
dc.language.isoenen_AU
dc.publisherElsevieren_AU
dc.subjectNeutron dosimetryen_AU
dc.subjectPolyethylenesen_AU
dc.subjectFast neutronsen_AU
dc.subjectRadiation detectorsen_AU
dc.subjectThicknessen_AU
dc.subjectWeighting functionsen_AU
dc.titleFrom imaging to dosimetry: GEANT4-based study on the application of medipix to neutron dosimetryen_AU
dc.typeConference Posteren_AU
Files
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: