Description of ANSTO’s confocal microprobe simulation program

dc.contributor.authorCohen, DDen_AU
dc.contributor.authorCrawford, Jen_AU
dc.contributor.authorSiegele, Ren_AU
dc.date.accessioned2011-02-28T03:20:24Zen_AU
dc.date.available2011-02-28T03:20:24Zen_AU
dc.date.issued2011-02-01en_AU
dc.date.statistics2011-02-01en_AU
dc.description.abstractThe elemental composition of a sample can be determined by the analysis of its characteristic X-ray spectrum. Proton induced X-ray emission (PIXE) has been used for a number of decades for this purpose (e.g. Clayton et al. 1981). More recently techniques aimed at enhancing the spatial resolution in the samples have been investigated. One of these techniques is to restrict the field of view of the X-ray detector by the use of a polycapillary lens. In such a confocal set-up the sample is driven across the sensitive volume formed at the intersection of the proton beam and the area from which the lens collects radiation (Zitnik at al. 2009, Wolff et al. 2009). Here we detail early investigations of a set-up with a polycapilary lens attached to the detector and a FORTRAN program which calculates the yield from a homogeneous material. Once the working of the set-up and program have been investigated and validated for homogeneous sample, heterogeneous samples can be considered.en_AU
dc.identifier.citationCohen, D. D., Crawford, J., & Siegele, R. (2011). Description of ansto's confocal microprobe simulation program (ANSTO/E772). Lucas Heights, NSW: Australian Nuclear Science and Technology Organisation.en_AU
dc.identifier.govdoc3221en_AU
dc.identifier.isbn1921268115en_AU
dc.identifier.issn1030-7745en_AU
dc.identifier.placeofpublicationLucas Heights, New South Walesen_AU
dc.identifier.urihttp://apo.ansto.gov.au/dspace/handle/10238/3094en_AU
dc.language.isoenen_AU
dc.publisherAustralian Nuclear Science and Technology Organisationen_AU
dc.relation.ispartofseriesANSTO External Reports;en_AU
dc.relation.ispartofseriesANSTO-E-772en_AU
dc.subjectANSTOen_AU
dc.subjectSimulationen_AU
dc.subjectPIXE analysisen_AU
dc.subjectSpatial resolutionen_AU
dc.subjectLensesen_AU
dc.subjectX-ray detectionen_AU
dc.titleDescription of ANSTO’s confocal microprobe simulation programen_AU
dc.typeExternal Reporten_AU
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
ANSTO-E-772.pdf
Size:
598.82 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: