A fast switching electrostatic deflector system for actinide isotopic ratio measurements

dc.contributor.authorZorko, Ben_AU
dc.contributor.authorChild, DPen_AU
dc.contributor.authorHotchkis, MACen_AU
dc.date.accessioned2010-07-05T02:20:52Zen_AU
dc.date.available2010-07-05T02:20:52Zen_AU
dc.date.issued2010-04-01en_AU
dc.date.statistics2010-04-01en_AU
dc.descriptionPhysical copy held by ANSTO Library at DDC 539.7.56en_AU
dc.description.abstractWe have implemented a fast switching electrostatic system on the actinides beamline on the ANTARES accelerator at ANSTO, to improve the precision of analyses by accelerator mass spectrometry. This high-energy bouncing system is based on a pair of deflector plates, deflecting in the orbit plane, set at the entrance and exit of the analysing magnet. The design of deflector plates is unique, and it was modelled by SIMION in order to minimize field inhomogenity and fringe field effects. The pair of deflector plates are supplied by a high-voltage amplifier driven by an EPICS-enabled control unit, with two 4 W power supplies providing up to ±10 kV modulation. The high-energy bouncing system is synchronized with the existing low-energy bouncing system. To measure the isotopic ratio with the new system, the magnetic fields of the injector and analysing magnets are set to transmit selected isotopes along the beam line with zero voltage applied. The other isotopes of interest are transmitted by keeping the magnetic fields constant and modulating the voltages on the injector magnet chamber and on the high-energy deflector plates. © 2009 Elsevier B.V.en_AU
dc.identifier.citationZorko, B., Child, D. P., & Hotchkis, M. A. C. (2010). A fast switching electrostatic deflector system for actinide isotopic ratio measurements. Paper presented to the 11th International Conference on Accelerator Mass Spectrometry (AMS-11), 14th – 19th September 2008. Spazio Etoile, Rome. In Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 268(7-8), 827-829. doi:10.1016/j.nimb.2009.10.041en_AU
dc.identifier.conferenceenddate19 September 2008en_AU
dc.identifier.conferencename11th International Conference on Accelerator Mass Spectrometry (AMS-11)en_AU
dc.identifier.conferenceplaceSpazio Etoile, Romeen_AU
dc.identifier.conferencestartdate14 September 2008en_AU
dc.identifier.govdoc1853en_AU
dc.identifier.issn0168-583Xen_AU
dc.identifier.issue45145en_AU
dc.identifier.issue7-8en_AU
dc.identifier.journaltitleNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atomsen_AU
dc.identifier.pagination827-829en_AU
dc.identifier.urihttp://dx.doi.org/10.1016/j.nimb.2009.10.041en_AU
dc.identifier.urihttp://apo.ansto.gov.au/dspace/handle/10238/1753en_AU
dc.identifier.volume268en_AU
dc.language.isoenen_AU
dc.publisherElsevieren_AU
dc.subjectANTARES Tandem Acceleratoren_AU
dc.subjectActinidesen_AU
dc.subjectSafeguardsen_AU
dc.subjectElectrostaticsen_AU
dc.subjectANSTOen_AU
dc.subjectMagnetic fieldsen_AU
dc.titleA fast switching electrostatic deflector system for actinide isotopic ratio measurementsen_AU
dc.typeConference Paperen_AU