The radiation dose incurred from the administration of 'SKELTEC'

dc.contributor.authorHetherington, ELRen_AU
dc.date.accessioned2007-11-22T04:22:21Zen_AU
dc.date.accessioned2010-04-30T04:30:45Zen_AU
dc.date.available2007-11-22T04:22:21Zen_AU
dc.date.available2010-04-30T04:30:45Zen_AU
dc.date.issued1973-03en_AU
dc.description.abstractThe Medical Internal Radiation Dose Committee method was used to calculate the radiation dose to the skeleton, bone marrow, kidneys, liver and whole body for a 10 mCi dose of 99mTc in the form of 'Skeltec' a thermostable technetium compound for bone scanning. Activity concentration in these organs was determined from both published and unpublished results of phantom, biopsy, and animal experiments. The calculated doses compare favourably with those published for the widely used bone scanning agent 18F.en_AU
dc.identifier.citationHetherington, E. L. R. (1980). The radiation dose incurred from the administration of 'SKELTEC'. (AAEC/E247). Lucas Heights, NSW: Australian Atomic Energy Commission.en_AU
dc.identifier.govdoc241en_AU
dc.identifier.isbn0642995397en_AU
dc.identifier.otherAAEC-E-247en_AU
dc.identifier.placeofpublicationLucas Heights, New South Walesen_AU
dc.identifier.urihttp://apo.ansto.gov.au/dspace/handle/10238/436en_AU
dc.language.isoen_auen_AU
dc.publisherAustralian Atomic Energy Commissionen_AU
dc.subjectRadiation dosesen_AU
dc.subjectSkeletonen_AU
dc.subjectBone marrowen_AU
dc.subjectBiopsyen_AU
dc.titleThe radiation dose incurred from the administration of 'SKELTEC'en_AU