dc.description.abstractTwo-phase-flow stability can be analysed with the TOSCLE code. TOSCLE uses equations derived by linearising and taking Laplace transformations of the mass, energy and momentum conservation equations and solving the resultant one-space-dimension equations analytically along a straight, uniform cross-section pipe with uniform heat addition or removal per unit length. Separate solutions are obtained for single-phase regions and two-phase regions of the pipe. Single-phase regions can be either subcooled liquid or superheated vapour. Complicated circuits can be analysed by subdividing the components until they conform to the "straight, uniform cross-section, uniform heat" description. The code calculates steady-state pressure drop for given inlet velocity, then perturbed pressure drop for given inlet velocity perturbation. The latter calculation is repeated at a number of frequencies to permit the drawing of a Nyquist plot of the inlet velocity to pressure drop transfer function from which stability is assessed. A simple slip correlation is incorporated as well as a two-phase-friction multiplier, which is taken as a quadratic in quality. Localised restrictions are permitted. The deficiencies of the analysis are a neglect of subcooled boiling and of variations in fluid saturation properties with pressure. The assumption of uniform power requires more subdivision of the circuit than would otherwise be necessary and the simple slip correlation is inaccurate near unit void fraction.en_AU
dc.identifier.citationSpinks, N. (1971). Analysis of flow stability in boiling systems with the TOSCLE code (AAEC/E217). Lucas Heights, NSW: Australian Atomic Energy Commission.en_AU
dc.identifier.govdoc226en_AU
dc.identifier.isbn064299417Xen_AU
dc.identifier.otherAAEC-E-217en_AU
dc.identifier.placeofpublicationLucas Heights, New South Walesen_AU
dc.identifier.urihttp://apo.ansto.gov.au/dspace/handle/10238/404en_AU
dc.language.isoen_auen_AU
dc.publisherAustralian Atomic Energy Commissionen_AU
dc.subjectTwo-phase flowen_AU
dc.subjectEquationsen_AU
dc.subjectDistributionen_AU
dc.subjectVelocityen_AU
dc.titleAnalysis of flow stability in boiling systems with the TOSCLE codeen_AU

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
AAEC-E-217.pdf
Size:
663.96 KB
Format:
Adobe Portable Document Format