Adaptation of a Freon-12 critical heat flux correlation to correlate water data from uniformly heated vertical tubes, Part I - based on critical heat flux data for water at pressures of 3 to 14 MPa

dc.contributor.authorGreen, WJen_AU
dc.date.accessioned2007-11-22T04:18:17Zen_AU
dc.date.accessioned2010-04-30T04:29:40Zen_AU
dc.date.available2007-11-22T04:18:17Zen_AU
dc.date.available2010-04-30T04:29:40Zen_AU
dc.date.issued1981-12en_AU
dc.description.abstractComparisons have been made between experimental critical heat flux (CHF) data for upflow of water in uniformly heated vertical tubes and values calculated from an empirical CHF correlation developed from Freon-12 data. When this correlation is re-evaluated to account for vapour Prandtl number effects very good agreement is obtained between experimental data and calculated values over a wide range of coolant conditions. Comparison of values calculated from the revised correlation with 2063 sets of CHF data obtained from experiments with water in vertical uniformly heated tubes shows a mean ratio of the calculated to experimental CHF of 0.82 and an r.m.s. error of 5.8 per cent for the following coolant conditions: (1) local pressure of 3.4 to 12 MPa; (2) mass flux greater than approx. 300 kg s-1m - 2 and (3) thermal equilibrium value of exit quality greater than 0.1.en_AU
dc.identifier.citationGreen, W. J. (1981). Adaptation of a freon-12 critical heat flux correlation to correlate water data from uniformly heated vertical tubes. Part 1 : based on critical heat flux data for water at pressures of 3 to 14 MPa (AAEC/E532). Lucas Heights, NSW: Australian Atomic Energy Commission, Research Establishment.en_AU
dc.identifier.govdoc174en_AU
dc.identifier.isbn0642597391en_AU
dc.identifier.otherAAEC-E-532en_AU
dc.identifier.placeofpublicationLucas Heights, New South Walesen_AU
dc.identifier.urihttp://apo.ansto.gov.au/dspace/handle/10238/277en_AU
dc.language.isoen_auen_AU
dc.publisherAustralian Atomic Energy Commissionen_AU
dc.subjectCritical heat fluxen_AU
dc.subjectFreonsen_AU
dc.subjectLiquid flowen_AU
dc.subjectExperimental dataen_AU
dc.titleAdaptation of a Freon-12 critical heat flux correlation to correlate water data from uniformly heated vertical tubes, Part I - based on critical heat flux data for water at pressures of 3 to 14 MPaen_AU