dc.description.abstractThe iodine activity taken up by thyroid is measured by a collimated 7.6x7.6cm NaI crystal, usually following an Iodine incident. To perform a dose assessment of the subject, the ICRP biokinetic retention model, given in ICRP54 publication, is applied to estimate the activity intake in thyroid and whole boy. The dose/activity conversion factors from ICRP68 are then applied to obtain the corresponding committed doses (effective & equivalent) of the subject. The 5um AMAD for inhalation route is applied in most cases. Follow up measurements are usually carried out when the Intake exceeds 5 kBq. The results are then compared with the predicted dose by the biokinetic model; adjustment to the model is applied to fit the measured data of individual (if required). The ICRP biokinetic model provides a satisfactory estimate to all encountered cases.en_AU
dc.description.sponsorshipLos Alamos National Laboratory; Lovelace Respiratory Research Institute.en_AU
dc.identifier.citationMeriaty, H. (2009). Occupational dose assessment of iodine intake at Australian Nuclear Science & Technology Organisation. Poster presented to the 10th International Conference on the Health Effects of Incorporated Radionuclides, 10th - 14th May 2009. Santa Fe, New Mexico, United States of America: La Fonda Hotel.en_AU
dc.identifier.conferenceenddate14 May 2009en_AU
dc.identifier.conferencename10th International Conference on the Health Effects of Incorporated Radionuclidesen_AU
dc.identifier.conferenceplaceSanta Fe, New Mexicoen_AU
dc.identifier.conferencestartdate10 May 2009en_AU
dc.identifier.govdoc1041en_AU
dc.identifier.urihttp://apo.ansto.gov.au/dspace/handle/10238/1610en_AU
dc.language.isoenen_AU
dc.publisherAustralian Nuclear Science and Technology Organisationen_AU
dc.subjectANSTOen_AU
dc.subjectIodineen_AU
dc.subjectDosesen_AU
dc.subjectDose ratesen_AU
dc.subjectOccupational exposureen_AU
dc.subjectIntakeen_AU
dc.titleOccupational dose assessment of iodine intake at Australian Nuclear Science & Technology Organisationen_AU
dc.typeConference Posteren_AU
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
occupationaldoseassessmentofiodineintakeatansto-meriaty-101101172537-phpapp01.pdf
Size:
174.11 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.78 KB
Format:
Plain Text
Description: