Status of the x-ray absorption spectroscopy (XAS) beamline at the Australian synchrotron
Loading...
Date
2007-02-02
Journal Title
Journal ISSN
Volume Title
Publisher
American Institute of Physics
Abstract
We present herein the current status of the X-ray Absorption Spectroscopy (XAS) Beamline at the 3 GeV Australian Synchrotron. The optical design and performance, details of the insertion device (Wiggler), end station
capabilities and construction and commissioning timeline are given.
Description
Keywords
Synchrotron radiation, Beams, Absorption spectroscopy, Australia, Synchrotrons, X-ray spectroscopy
Citation
Glover, C., McKinlay, J., Clift, J., Barg, M., Boldeman, J., & Ridgway, M., Foran, G., Garrett, R., Lay, P., & Broadbent, A. (2007). Status of the x-ray absorption spectroscopy (XAS) beamline at the Australian synchrotron. Paper presented to the X-Ray Absorption Fine Structure – XAFS13: 13th International Conference, 9th – 14th July 2006, Stanford, California, In B. Hedman & P. Pianetta (Eds.), AIP Conference Proceedings, Volume 882, (pp. 884-886). Stanford, California, United States of America: Stanford University. doi:10.1063/1.2644692