Cylindrical silicon-on-insulator microdosimeter: charge collection characteristics.

dc.contributor.authorZiebell, ALen_AU
dc.contributor.authorLim, WHen_AU
dc.contributor.authorReinhard, MIen_AU
dc.contributor.authorCornelius, IMen_AU
dc.contributor.authorProkopovich, DAen_AU
dc.contributor.authorSiegele, Ren_AU
dc.contributor.authorDzurak, ASen_AU
dc.contributor.authorRosenfeld, ABen_AU
dc.date.accessioned2009-12-16T04:53:23Zen_AU
dc.date.accessioned2010-04-30T04:56:45Zen_AU
dc.date.available2009-12-16T04:53:23Zen_AU
dc.date.available2010-04-30T04:56:45Zen_AU
dc.date.issued2007-11-22en_AU
dc.date.statistics2007-11-22en_AU
dc.description.abstractAt present there exists a need, in both medical physics and radiation protection, for a portable microdosimeter that can be used in determining the radiobiological effectiveness (RBE) of different mixed radiation fields.en_AU
dc.description.sponsorshipAustralian Institute of Nuclear Science and Engineering (AINSE); Vacuum Society of Australia (VSA); Australian Research Council (ARC); Australian Research Network for Advanced Materials (ARNAM); JAVAC; Nanotechnology Network; ThermoFisher Scientificen_AU
dc.identifier.citationZiebell, A. L., Lim, W. H., Reinhard, M. I., Cornelius, I., Prokopovich, D. A., & Siegele, R., Dzurak, A. S., & Rosenfeld, A. B. (2007). Cylindrical silicon-on-insulator microdosimeter: charge collection characteristics. Paper presented to the 15th Australian Conference on Nuclear and Complementary Techniques of Analysis and 9th Vacuum Society of Australia Congress, 21st – 23rd November 2007. In Proceedings of the 15th Australian conference on nuclear and complementary techniques of analysis and 9th Vacuum Society of Australia congress, (pp. 66). Melbourne, Australia: University of Melbourne.en_AU
dc.identifier.conferenceenddate23 November 2007en_AU
dc.identifier.conferencename15th Australian Conference on Nuclear and Complementary Techniques of Analysis and 9th Vacuum Society of Australia Congressen_AU
dc.identifier.conferenceplaceMelbourne, Australiaen_AU
dc.identifier.conferencestartdate21 November 2007en_AU
dc.identifier.govdoc1020en_AU
dc.identifier.isbn0975843427en_AU
dc.identifier.pagination66en_AU
dc.identifier.urihttp://apo.ansto.gov.au/dspace/handle/10238/2694en_AU
dc.language.isoenen_AU
dc.publisherAustralian Institute of Nuclear Science and Engineering (AINSE)en_AU
dc.subjectSiliconen_AU
dc.subjectMicrodosimetryen_AU
dc.subjectCylindrical configurationen_AU
dc.subjectBiological radiation effectsen_AU
dc.subjectRBEen_AU
dc.subjectPortable equipmenten_AU
dc.titleCylindrical silicon-on-insulator microdosimeter: charge collection characteristics.en_AU
dc.typeConference Presentationen_AU
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
ZIEBELL_Cylindrical_Silicon_Insulator_Microdosimeter_2007_11.pdf
Size:
2.19 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.79 KB
Format:
Plain Text
Description: