Cylindrical silicon-on-insulator microdosimeter: charge collection characteristics.
dc.contributor.author | Ziebell, AL | en_AU |
dc.contributor.author | Lim, WH | en_AU |
dc.contributor.author | Reinhard, MI | en_AU |
dc.contributor.author | Cornelius, IM | en_AU |
dc.contributor.author | Prokopovich, DA | en_AU |
dc.contributor.author | Siegele, R | en_AU |
dc.contributor.author | Dzurak, AS | en_AU |
dc.contributor.author | Rosenfeld, AB | en_AU |
dc.date.accessioned | 2009-12-16T04:53:23Z | en_AU |
dc.date.accessioned | 2010-04-30T04:56:45Z | en_AU |
dc.date.available | 2009-12-16T04:53:23Z | en_AU |
dc.date.available | 2010-04-30T04:56:45Z | en_AU |
dc.date.issued | 2007-11-22 | en_AU |
dc.date.statistics | 2007-11-22 | en_AU |
dc.description.abstract | At present there exists a need, in both medical physics and radiation protection, for a portable microdosimeter that can be used in determining the radiobiological effectiveness (RBE) of different mixed radiation fields. | en_AU |
dc.description.sponsorship | Australian Institute of Nuclear Science and Engineering (AINSE); Vacuum Society of Australia (VSA); Australian Research Council (ARC); Australian Research Network for Advanced Materials (ARNAM); JAVAC; Nanotechnology Network; ThermoFisher Scientific | en_AU |
dc.identifier.citation | Ziebell, A. L., Lim, W. H., Reinhard, M. I., Cornelius, I., Prokopovich, D. A., & Siegele, R., Dzurak, A. S., & Rosenfeld, A. B. (2007). Cylindrical silicon-on-insulator microdosimeter: charge collection characteristics. Paper presented to the 15th Australian Conference on Nuclear and Complementary Techniques of Analysis and 9th Vacuum Society of Australia Congress, 21st – 23rd November 2007. In Proceedings of the 15th Australian conference on nuclear and complementary techniques of analysis and 9th Vacuum Society of Australia congress, (pp. 66). Melbourne, Australia: University of Melbourne. | en_AU |
dc.identifier.conferenceenddate | 23 November 2007 | en_AU |
dc.identifier.conferencename | 15th Australian Conference on Nuclear and Complementary Techniques of Analysis and 9th Vacuum Society of Australia Congress | en_AU |
dc.identifier.conferenceplace | Melbourne, Australia | en_AU |
dc.identifier.conferencestartdate | 21 November 2007 | en_AU |
dc.identifier.govdoc | 1020 | en_AU |
dc.identifier.isbn | 0975843427 | en_AU |
dc.identifier.pagination | 66 | en_AU |
dc.identifier.uri | http://apo.ansto.gov.au/dspace/handle/10238/2694 | en_AU |
dc.language.iso | en | en_AU |
dc.publisher | Australian Institute of Nuclear Science and Engineering (AINSE) | en_AU |
dc.subject | Silicon | en_AU |
dc.subject | Microdosimetry | en_AU |
dc.subject | Cylindrical configuration | en_AU |
dc.subject | Biological radiation effects | en_AU |
dc.subject | RBE | en_AU |
dc.subject | Portable equipment | en_AU |
dc.title | Cylindrical silicon-on-insulator microdosimeter: charge collection characteristics. | en_AU |