Abstract
The calculation of resonance shielding by the subgroup method as incorporated in the MIRANDA module of the AUS neutronics code system is compared with Monte Carlo calculatons for a number of thermal reactor lattices. For the large range of single rod and rod cluster lattices considered AUS results for resonance absorption were high by up to two per cent.
Description
Keywords
Neutrons, Resonance absorption, Reactor lattices, Fuel rods, Fuel elements, HIFAR Reactor