Dosimetry and irradiation methods for the ANSTO gamma technology research irradiator (GATRI).

dc.contributor.authorIzard, MEen_AU
dc.date.accessioned2007-11-22T04:27:05Zen_AU
dc.date.accessioned2010-04-30T04:38:04Zen_AU
dc.date.available2007-11-22T04:27:05Zen_AU
dc.date.available2010-04-30T04:38:04Zen_AU
dc.date.issued1988-07en_AU
dc.description.abstractThe Australian Nuclear Science and Technology Organisation's gamma technology research irradiator (GATRI) at Lucas Heights New South Wales has been modified for use as a research and small-scale commercial irradiation facility to be available to government agencies and private industry for the technical and economic evaluation of irradiation processing. The new source rack was designed around existing mechanical components to optimise the limited space available within the irradiation cell. Irradiation parameters investigated during commissioning included the effect of source-to-target distance on relative dose rates within targets of the same density; effect of density on dose-rate distribution within targets irradiated at the same distance from the source; and the contribution of transit dose to low absorbed doses as the source is raised and lowered. The efficiency of the irradiator was determined for various target densities and overdose ratios.en_AU
dc.identifier.citationIzard, M. E. (1988). Dosimetry and irradiation methods for the ANSTO gamma technology research irradiator (GATRI) (ANSTO/E679). Lucas Heights, NSW: Australian Nuclear Science and Technology Organisation.en_AU
dc.identifier.govdoc656en_AU
dc.identifier.isbn0642598886en_AU
dc.identifier.issn10307745en_AU
dc.identifier.otherANSTO-E-679en_AU
dc.identifier.placeofpublicationLucas Heights, New South Walesen_AU
dc.identifier.urihttp://apo.ansto.gov.au/dspace/handle/10238/646en_AU
dc.language.isoen_auen_AU
dc.publisherAustralian Nuclear Science and Technology Organisationen_AU
dc.subjectRadioisotopesen_AU
dc.subjectANSTOen_AU
dc.subjectDosimetryen_AU
dc.subjectGamma sourcesen_AU
dc.subjectIrradiation plantsen_AU
dc.subjectCobalt 60en_AU
dc.titleDosimetry and irradiation methods for the ANSTO gamma technology research irradiator (GATRI).en_AU