Measurement of the dynamic response of the materials testing reactor HIFAR

dc.contributor.authorHarries, JRen_AU
dc.contributor.authorWilson, DJen_AU
dc.date.accessioned2007-11-22T04:27:04Zen_AU
dc.date.accessioned2010-04-30T04:38:03Zen_AU
dc.date.available2007-11-22T04:27:04Zen_AU
dc.date.available2010-04-30T04:38:03Zen_AU
dc.date.issued1978-01en_AU
dc.description.abstractPower transients were initiated in the HIFAR Materials Testing Reactor by altering both the temperature of the primary coolant circuit and the flow rate of the primary coolant. Analysis of the time variation of the reactor power and the D2O temperature provided information about the flow of D2O in the reactor aluminium tank and the time response of the negative power coefficient. The experimental power transients were compared with calculations carried out with the HIDYN code, which combines the neutron kinetics with the primary coolant characteristics.en_AU
dc.identifier.citationHarries, J. H., Wilson, D. J. (1978). Measurement of the dynamic response of the materials testing reactor HIFAR. (AAEC/S5). Lucas Heights, NSW: Australian Atomic Energy Commission.en_AU
dc.identifier.citationReactor kineticsen_AU
dc.identifier.govdoc655en_AU
dc.identifier.isbn0642596395en_AU
dc.identifier.otherAAEC-E-428en_AU
dc.identifier.placeofpublicationLucas Heights, New South Walesen_AU
dc.identifier.urihttp://apo.ansto.gov.au/dspace/handle/10238/645en_AU
dc.language.isoen_auen_AU
dc.publisherAustralian Atomic Energy Commissionen_AU
dc.subjectHIFAR Reactoren_AU
dc.subjectTransientsen_AU
dc.subjectReactor cooling systemsen_AU
dc.subjectReactivityen_AU
dc.subjectTemperature coefficienten_AU
dc.titleMeasurement of the dynamic response of the materials testing reactor HIFARen_AU
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
AAEC-E-428.pdf
Size:
894.93 KB
Format:
Adobe Portable Document Format
Description: