Measurement of a modified relative conversion ratio in multi-rod clusters

dc.contributor.authorDuerden, Pen_AU
dc.date.accessioned2007-11-22T04:24:26Zen_AU
dc.date.accessioned2010-04-30T04:36:20Zen_AU
dc.date.available2007-11-22T04:24:26Zen_AU
dc.date.available2010-04-30T04:36:20Zen_AU
dc.date.issued1975-09en_AU
dc.description.abstractAn Indo-Australian experiment is described in which relative conversion ratios for a range of U02 rod cluster fuel elements in a heavy water moderated reactor were measured using a high resolution Ge(Li) detector to measure directly the neptunium activity following neutron capture in 238U. The results are compared with calculations made with the UKAEA lattice code WIMSen_AU
dc.identifier.citationDuerden, P. (1975). Measurement of a modified relative conversion ratio in multi-rod clusters. (AAEC/E339). Lucas Heights, NSW: Australian Atomic Energy Commission.en_AU
dc.identifier.govdoc553en_AU
dc.identifier.isbn064299689Xen_AU
dc.identifier.otherAAEC-E-339en_AU
dc.identifier.placeofpublicationLucas Heights, New South Walesen_AU
dc.identifier.urihttp://apo.ansto.gov.au/dspace/handle/10238/543en_AU
dc.language.isoen_auen_AU
dc.publisherAustralian Atomic Energy Commission.en_AU
dc.subjectConversion ratioen_AU
dc.subjectFission productsen_AU
dc.subjectFuel rodsen_AU
dc.subjectThermal neutronsen_AU
dc.titleMeasurement of a modified relative conversion ratio in multi-rod clustersen_AU
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
AAEC-E-339.pdf
Size:
1.42 MB
Format:
Adobe Portable Document Format
Description: