Burnout data from annuli cooled by upflow of FREON-12.

dc.contributor.authorIlic, Ven_AU
dc.date.accessioned2007-11-22T04:24:07Zen_AU
dc.date.accessioned2010-04-30T04:35:55Zen_AU
dc.date.available2007-11-22T04:24:07Zen_AU
dc.date.available2010-04-30T04:35:55Zen_AU
dc.date.issued1974-11en_AU
dc.description.abstractBurnout and pressure drop data are presented for a series of 29 annuli cooled by upflow of Freon-12 at an inlet pressure of 1.04 MPa with internal, external and combined internal and external heating. The test sections had a uniform axial heat flux distribution, except for one internally heated test section which had a chopped cosine axial heat flux profile (form factor = 1.4) The test sections covered a range of annulus goemetries; heated lengths range from 457 mm to 4,277 mm; hydraulic and internal tube diameter ranges are 1.55 mm to 8 mm and 8 mm to 19 mm respectively. The mass velocity range is 0.7 to 4 Mg m-2s-1, and inlet subcooling values range up to 26 kJ kg-1.en_AU
dc.identifier.citationIlic, V. (1974). Burnout data from annuli cooled by upflow of FREON-1 (AAEC/E323). Lucas Heights, NSW: Australian Atomic Energy Commissionen_AU
dc.identifier.govdoc536en_AU
dc.identifier.isbn0642996601en_AU
dc.identifier.otherAAEC-E-323en_AU
dc.identifier.placeofpublicationLucas Heights, New South Walesen_AU
dc.identifier.urihttp://apo.ansto.gov.au/dspace/handle/10238/526en_AU
dc.language.isoen_auen_AU
dc.publisherAustralian Atomic Energy Commissionen_AU
dc.subjectBurnouten_AU
dc.subjectCritical heat fluxen_AU
dc.subjectFreonsen_AU
dc.subjectFlow rateen_AU
dc.subjectPressure dropen_AU
dc.titleBurnout data from annuli cooled by upflow of FREON-12.en_AU