A comparison between experimentally determined flow instability thresholds and calculations using the computer code toscle

dc.contributor.authorWilson, DJen_AU
dc.date.accessioned2007-11-22T04:23:27Zen_AU
dc.date.accessioned2010-04-30T04:35:18Zen_AU
dc.date.available2007-11-22T04:23:27Zen_AU
dc.date.available2010-04-30T04:35:18Zen_AU
dc.date.issued1973-12en_AU
dc.description.abstractExperimental results from the Canadian forced convection loop FLARE (D'Arcy 1968) have been used to assess the value of the TOSCLE computer code (Spinks 1971) for calculating flow stability characteristics of pressure tube reactor systems. Good agreement has been found between TOSCLE calculations and the FLARE results for high values of subcooling. TOSCLE indicated a crucial boiling length as supposed by Shotkin (1967) . However, this does not appear to be consistent with the FLARE experimental data and large discrepancies occur at low subcoolings. The experimental results showed an increased scatter in the low subcooling region. A possible cause for this and for the discrepancy with calculated results at low subcooling are suggested. The sensitivity of TOSCLE results to various input parameters was examined. Most parameter variations were found to have only a minor effect on the results. Further experimental work in conjunction with detailed theoretical analysis is essential, particularly in the area of low subcooling which is of great importance in power reactor design.en_AU
dc.identifier.citationWilson, D. J. (1973). A comparison between experimentally determined flow instability thresholds and calculations using the computer code toscle (AAEC/E296). Lucas Heights, NSW: Australian Atomic Energy Commission.en_AU
dc.identifier.govdoc503en_AU
dc.identifier.isbn064299613Xen_AU
dc.identifier.otherAAEC-E-296en_AU
dc.identifier.placeofpublicationLucas Heights, New South Walesen_AU
dc.identifier.urihttp://apo.ansto.gov.au/dspace/handle/10238/493en_AU
dc.language.isoen_auen_AU
dc.publisherAustralian Atomic Energy Commissionen_AU
dc.subjectComparative evaluationsen_AU
dc.subjectT codesen_AU
dc.subjectPressure tube reactorsen_AU
dc.subjectCoolant loopsen_AU
dc.subjectTwo-phase flowen_AU
dc.subjectSubcoolingen_AU
dc.titleA comparison between experimentally determined flow instability thresholds and calculations using the computer code toscleen_AU
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
AAEC-E-296.pdf
Size:
489 KB
Format:
Adobe Portable Document Format
Description: