Performance of a thermosiphon evaporator for concentration of uranyl nitrate solutions

dc.contributor.authorLevins, DMen_AU
dc.contributor.authorAlfredson, PGen_AU
dc.date.accessioned2007-11-22T04:23:04Zen_AU
dc.date.accessioned2010-04-30T04:34:58Zen_AU
dc.date.available2007-11-22T04:23:04Zen_AU
dc.date.available2010-04-30T04:34:58Zen_AU
dc.date.issued1973-05en_AU
dc.description.abstractThe performance of a thermosiphon evaporator, with a heat transfer area of 0.74 m2, for the concentration of uranyl nitrate solutions up to 1000 gU ℓ-1 is evaluated. The effects of steam pressure, uranium concentration and liquid submergence on the overall heat transfer coefficient are reported and a method of designing thermosiphon evaporators handling concentrated uranyl nitrate solutions is proposed. Pressure drop characteristics of two packings used in the steam stripping and de-entrainment sections of the evaporator are also given. Overall heat transfer coefficients in the range 1.4 - 2.5 kW m-1 K-1 were obtained at uranyl nitrate concentrations up to 1000 gU ℓ-l. Heat transfer to uranyl nitrate solutions below a concentration of 100 gU ℓ-1 was satisfactorily predicted by employing conventional heat transfer correlations using physical property data for water. Results for more concentrated solutions were successfully correlated using an empirical correction factor which accounts for the change in physical properties of the boiling solution with concentration.en_AU
dc.identifier.citationLevins, D., & Alfredson, P. (1973). Performance of a thermosiphon evaporator for concentration of uranyl nitrate solutions (AAEC/E278). Lucas Heights N.S.W.: Australian Atomic Energy Commission, Research Establishment.en_AU
dc.identifier.govdoc483en_AU
dc.identifier.isbn0642995656en_AU
dc.identifier.otherAAEC-E-278en_AU
dc.identifier.placeofpublicationLucas Heights, New South Walesen_AU
dc.identifier.urihttp://apo.ansto.gov.au/dspace/handle/10238/473en_AU
dc.language.isoen_auen_AU
dc.publisherAustralian Atomic Energy Commissionen_AU
dc.subjectHeat transferen_AU
dc.subjectUraniumen_AU
dc.subjectPurificationen_AU
dc.subjectUranyl nitratesen_AU
dc.subjectSolvent extractionen_AU
dc.titlePerformance of a thermosiphon evaporator for concentration of uranyl nitrate solutionsen_AU
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
AAEC-E-278.pdf
Size:
889.73 KB
Format:
Adobe Portable Document Format
Description: