Abstract
The delayed gamma-ray emission in 252Cf spontaneous fission has been studied using a lithium drifted germanium detector. In the time range 300 nanoseconds to 5 microseconds after fission a number of gamma rays were seen and their half-lives and intensities were measured. The results are compared with a recent investigation which used a different experimental method.
Description
Keywords
Gamma radiation, Fission, Californium 252, Data analysis, GE semiconductor detectors, Lithium
Citation
Ajitanand, N. (1971). Delayed gamma-ray emission in the spontaneous fission of californium-252 (AAEC/TM577). Lucas Heights, N.S.W.: Research Establishment, Australian Atomic Energy Commission.