Determination of zinc-65 in Lucas Heights effluent.
dc.contributor.author | Isaacs, SR | en_AU |
dc.date.accessioned | 2007-11-22T04:33:31Z | en_AU |
dc.date.accessioned | 2010-04-30T04:41:31Z | en_AU |
dc.date.available | 2007-11-22T04:33:31Z | en_AU |
dc.date.available | 2010-04-30T04:41:31Z | en_AU |
dc.date.issued | 1970-10 | en_AU |
dc.description.abstract | A method for the quantitative determination of zinc-65 in effluent is described. Zinc-65 is selectively extracted from a concentrate of effluent in HC1 using Aliquat-336 in xylene. The extracted zinc-65 is determined by gamma spectrometry. Using an 8 in x 4 in NaI(TI) cyrstal, concentrations as low as 0.07 x 10-12 Ci/ml can be determined, with + 10 per cent statistical accuracy. | en_AU |
dc.identifier.citation | Isaacs, S. R. (1970). Determination of zinc-65 in Lucas Heights effluent. (AAEC/TM569. Lucas Heights, NSW: Australian Atomic Energy Commission. | en_AU |
dc.identifier.govdoc | 868 | en_AU |
dc.identifier.isbn | 0642990939 | en_AU |
dc.identifier.other | AAEC-TM-569 | en_AU |
dc.identifier.placeofpublication | Lucas Heights, New South Wales | en_AU |
dc.identifier.uri | http://apo.ansto.gov.au/dspace/handle/10238/858 | en_AU |
dc.language.iso | en_au | en_AU |
dc.publisher | Australian Atomic Energy Commission | en_AU |
dc.subject | Zinc 65 | en_AU |
dc.subject | AAEC | en_AU |
dc.subject | Radioactive effluents | en_AU |
dc.subject | Xylenes | en_AU |
dc.subject | Gamma spectroscopy | en_AU |
dc.title | Determination of zinc-65 in Lucas Heights effluent. | en_AU |