Measurements of coarse control arm drop characteristics in the materials testing reactor HIFAR
dc.contributor.author | Marshall, J | en_AU |
dc.contributor.author | Blevins, RJ | en_AU |
dc.date.accessioned | 2007-11-22T04:18:00Z | en_AU |
dc.date.accessioned | 2010-04-30T04:32:59Z | en_AU |
dc.date.available | 2007-11-22T04:18:00Z | en_AU |
dc.date.available | 2010-04-30T04:32:59Z | en_AU |
dc.date.issued | 1983-02 | en_AU |
dc.description.abstract | Measurements were made of the angular position/time characteristics of a coarse control arm in the AAEC's materials testing reactor HIFAR following a trip. The method of measurement is described and the results are presented. It is clear that all of the measured transients may be reasonably fitted by a single differential equation. | en_AU |
dc.identifier.citation | Marshall, J., & Blevins, R. J. (1983). Measurements of coarse control arm drop characteristics in the materials testing reactor HIFAR (AAEC/E560). Lucas Heights, N.S.W.: Australian Atomic Energy Commission Research Establishment, Lucas Heights Research Laboratories. | en_AU |
dc.identifier.govdoc | 367 | en_AU |
dc.identifier.isbn | 0642597642 | en_AU |
dc.identifier.other | AAEC-E-560 | en_AU |
dc.identifier.uri | http://apo.ansto.gov.au/dspace/handle/10238/266 | en_AU |
dc.language.iso | en_au | en_AU |
dc.publisher | Australian Atomic Energy Commission | en_AU |
dc.subject | HIFAR Reactor | en_AU |
dc.subject | Differential equations | en_AU |
dc.subject | Measuring methods | en_AU |
dc.subject | Control elements | en_AU |
dc.subject | Reactor shutdown | en_AU |
dc.title | Measurements of coarse control arm drop characteristics in the materials testing reactor HIFAR | en_AU |