The determination of fission product levels in HIFAR heavy water
dc.contributor.author | Palmer, AR | en_AU |
dc.contributor.author | Porritt, REJ | en_AU |
dc.date.accessioned | 2007-11-22T04:15:29Z | en_AU |
dc.date.accessioned | 2010-04-30T04:32:53Z | en_AU |
dc.date.available | 2007-11-22T04:15:29Z | en_AU |
dc.date.available | 2010-04-30T04:32:53Z | en_AU |
dc.date.issued | 1968-01 | en_AU |
dc.description.abstract | Methods for the determination of Ba-140 and I-131 are described. These methods are suitable for routine monitoring of fission product levels in the HIFAR heavy water circuit. The results obtained over a four-month period are presented and discussed. | en_AU |
dc.identifier.citation | Palmer, A. R. & Porritt, R. E. J. (1968). The determination of fission product levels in HIFAR heavy water (AAEC/TM427). Lucas Heights, NSW: Australian Atomic Energy Commission Research Establishment. | en_AU |
dc.identifier.govdoc | 362 | en_AU |
dc.identifier.other | AAEC-TM-427 | en_AU |
dc.identifier.uri | http://apo.ansto.gov.au/dspace/handle/10238/242 | en_AU |
dc.language.iso | en_au | en_AU |
dc.publisher | Australian Atomic Energy Commission | en_AU |
dc.subject | Fission products | en_AU |
dc.subject | HIFAR Reactor | en_AU |
dc.subject | AAEC | en_AU |
dc.subject | Heavy water | en_AU |
dc.title | The determination of fission product levels in HIFAR heavy water | en_AU |