Examination of BeO irradiated at elevated temperatures in the engineering test reactor

dc.contributor.authorHickman, BSen_AU
dc.contributor.authorChute, JHen_AU
dc.date.accessioned2007-11-22T04:10:08Zen_AU
dc.date.accessioned2010-04-30T04:31:23Zen_AU
dc.date.available2007-11-22T04:10:08Zen_AU
dc.date.available2010-04-30T04:31:23Zen_AU
dc.date.issued1964-09en_AU
dc.description.abstractA description is given of an examination of BeO samples irradiated by the General Electric Co. in the Engineering Test Reactor, Idaho Fails, to doses up to 1.2 x 1021(> 1 MeV) and temperatures in the range 470 — 1200ºC, at dose rates of 1 to 3 x 1014 nv. The results of X—ray measurements and optical and electron microscopy are presented and discussed. Comparisons are made with previously reported results on similar material irradiated in the reactor HIFAR at lower dose rates.en_AU
dc.identifier.citationHickman, B. S. & Chute, J. (1964). Examination of BeO irradiated at elevated temperatures in the engineering test reactor. (AAEC/E130). Lucas Heights, NSW: Australian Atomic Energy Commission.en_AU
dc.identifier.govdoc277en_AU
dc.identifier.otherAAEC-E-130en_AU
dc.identifier.urihttp://apo.ansto.gov.au/dspace/handle/10238/77en_AU
dc.language.isoen_auen_AU
dc.publisherAustralian Atomic Energy Commissionen_AU
dc.subjectPost-irradiation examinationen_AU
dc.subjectX-ray diffractionen_AU
dc.subjectElectron microscopyen_AU
dc.subjectHIFAR Reactoren_AU
dc.titleExamination of BeO irradiated at elevated temperatures in the engineering test reactoren_AU