dc.description.abstractLung cancer is one of the world’s deadliest cancers, often not diagnosed until it has spread beyond the lung, in part due to limitations in current medical imaging. Insufficient detail in diagnostic images can mean that patients require a biopsy to gain a full understanding of their prognosis. Here, we investigate the use of propagation-based X-ray phase-contrast imaging to capture high-resolution region-of-interest 3D Computed-Tomography (CT) images of suspicious masses, using a human chest phantom. In this study, we imaged a 3.5 cm region within the chest phantom, with each CT slice amounting to approximately 1% of the area of the whole chest at that height. X-ray energies ranging from 50 to 80 keV and propagation distances of 0 to 7 m were tested. We were able to quantify the experimental parameters that would be required to increase soft-tissue sensitivity and spatial resolution relative to conventional X-ray imaging methods, and hence improve the capacity for tumour characterisation. Our results suggest that propagation-based phase-contrast region-of-interest CT imaging could enable better tumour visualisation, which may aid in earlier detection and a better outcome for lung cancer patients. © The Author(s) 2025. 0pen Access CC-BY-NC-ND 4.0en_AU
dc.description.sponsorshipWe thank Patrick Brennan and the University of Sydney for loaning the Lungman phantom. This research was undertaken on the Imaging and Medical Beamline (IMBL) at the Australian Synchrotron, part of ANSTO. We recognise scientific and technical assistance from Matthew Cameron and Anton Maksimenko and we thank the IMBL for the granted beamtime M18648 in 2022. We thank Emmanuel Brun for the suggestion of using whole-lung CT data in removing cupping artefacts. We acknowledge that this research was supported by an AINSE Ltd. Postgraduate Research Award (PGRA), an Australian Government Research Training Program (RTP) scholarship, and National Health and Medical Research Council (NMHRC) Synergy Grant APP2011204.en_AU
dc.format.mediumElectronicen_AU
dc.identifier.articlenumber19881en_AU
dc.identifier.citationCostello, L., Donnelley, M., Nesterets, Y., Ahlers, J., Alloo, S., Hall, C., Hausermann, D., Kitchen, M., D’Amico, L., & Morgan, K. (2025). Evaluating the feasibility of region-of-interest X-ray phase contrast imaging for lung cancer diagnostics. Scientific Reports, 15(1), 19881. doi:10.1038/s41598-025-04509-zen_AU
dc.identifier.issn2045-2322en_AU
dc.identifier.issue1en_AU
dc.identifier.journaltitleScientific Reportsen_AU
dc.identifier.urihttps://doi.org/10.1038/s41598-025-04509-zen_AU
dc.identifier.urihttps://apo.ansto.gov.au/handle/10238/17410en_AU
dc.identifier.volume15en_AU
dc.languageEnglishen_AU
dc.language.isoenen_AU
dc.publisherSpringer Natureen_AU
dc.subjectLungsen_AU
dc.subjectDiagnosisen_AU
dc.subjectDiagnostic techniquesen_AU
dc.subjectTumor cellsen_AU
dc.subjectBiopsyen_AU
dc.subjectPatientsen_AU
dc.subjectNeoplasmsen_AU
dc.subjectPhysicsen_AU
dc.subjectPhoton computed tomographyen_AU
dc.subjectMagnetic resonanceen_AU
dc.subjectBiopsyen_AU
dc.subjectContrast Mediaen_AU
dc.titleEvaluating the feasibility of region-of-interest X-ray phase contrast imaging for lung cancer diagnosticsen_AU
dc.typeJournal Articleen_AU
dcterms.dateAccepted2025-05-27en_AU

Files

Original bundle

Now showing 1 - 2 of 2
Loading...
Thumbnail Image
Name:
Evaluating the feasibility of region-of-interest X-ray phase contrast imaging for lung cancer diagnostics.pdf
Size:
2.76 MB
Format:
Adobe Portable Document Format
Description:
Published version
Loading...
Thumbnail Image
Name:
s41598-025-04509-z.pdf
Size:
2.76 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.66 KB
Format:
Plain Text
Description:

Collections