Performance test on neutron polarization analysis capability of PELICAN –time of flight cold neutron spectrometer

dc.contributor.authorD'Adam, TMen_AU
dc.contributor.authorLee, WTen_AU
dc.contributor.authorMole, RAen_AU
dc.contributor.authorYu, DHen_AU
dc.date.accessioned2021-08-24T22:41:35Zen_AU
dc.date.available2021-08-24T22:41:35Zen_AU
dc.date.issued2017-07-12en_AU
dc.date.statistics2021-08-17en_AU
dc.description.abstractThe implementation of polarization analysis on a conventional time-of-flight spectrometer has been a major instrumental goal for some time. Here we present our recent results describing our successful test of the polarization analysis option on the PELICAN spectrometer. The compact incident neutron polarization system is an integration of a solid-state bender-type supermirror polarizer with a gradient radio frequency (RF) spin flipper. Polarization analysis is achieved by using a polarized 3He neutron spin filter that covers a span of 120 degrees. The polarization analysis system is installed inside the high vacuum sample chamber through a dedicated aluminium vacuum adaptor flange. In-situ refilling of pre-generated polarized 3He gas has been implemented. The supermirror polarizer and spin flipper have been characterized with a Heusler crystal as the analyser for neutron wavelength of 4.68 Å. 95% polarization efficiency and 92% flipping efficiency have been obtained for the polarizer and spin flipper, respectively. It was found that the Fermi chopper had no depolarization effects. Further tests with the 3He analyse ron a non-magnetic alumina sample achieved overall polarization efficiency of 82% and this gives 94% analysing power for a 3He analyser filled with 1 bar of 3He gas. The T1 lifetime of the 3He cell is about 100 hours. Nuclear-spin incoherent scattering on vanadium has been performed and the 2:1 ratio between the spin-flip and non-spin-flip signal has been observed. The energy resolution of the conventional spectrometer was maintained and approximately 80 % of the detector area is still useable. More details of the instrument performance and further improvement on polarization analysis will be presented.en_AU
dc.identifier.citationD'Adam, T., Lee, W.-T., Mole, R. A., & Yu, D. (2017). Performance test on neutron polarization analysis capability of PELICAN –time of flight cold neutron spectrometer. Paper presented at ICNS 2017 (International Conference on Neutron Scattering), Daejeon, South Korea, 9 to 13 July 2017. Retrieved from: http://www.icns2017.org/program.phpen_AU
dc.identifier.conferenceenddate13 July 2017en_AU
dc.identifier.conferencenameICNS 2017 (International Conference on Neutron Scattering)en_AU
dc.identifier.conferenceplaceDaejeon, South Koreaen_AU
dc.identifier.conferencestartdate9 July 2017en_AU
dc.identifier.urihttp://www.icns2017.org/program.phpen_AU
dc.identifier.urihttps://apo.ansto.gov.au/dspace/handle/10238/11470en_AU
dc.language.isoenen_AU
dc.publisherInternational Conference on Neutron Scatteringen_AU
dc.subjectPolarizationen_AU
dc.subjectSpectrometersen_AU
dc.subjectSpinen_AU
dc.subjectNeutronsen_AU
dc.subjectScatteringen_AU
dc.subjectVanadiumen_AU
dc.titlePerformance test on neutron polarization analysis capability of PELICAN –time of flight cold neutron spectrometeren_AU
dc.typeConference Abstracten_AU
Files
Original bundle
Now showing 1 - 2 of 2
Loading...
Thumbnail Image
Name:
11_1016 Performance Test on Neutron Polarization Analysis Capability of PELICAN –Time of Flight Cold Neutron Spectrometer.pdf
Size:
4 KB
Format:
Adobe Portable Document Format
Description:
Loading...
Thumbnail Image
Name:
ICNS2017_final_program.pdf
Size:
5.42 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.63 KB
Format:
Item-specific license agreed upon to submission
Description: