Characterization of single ion tracks in PMMA created by light and heavy ion microprobes

dc.contributor.authorAlves, Aen_AU
dc.contributor.authorReichart, Pen_AU
dc.contributor.authorSiegele, Ren_AU
dc.contributor.authorJohnston, PNen_AU
dc.contributor.authorJamieson, DNen_AU
dc.date.accessioned2022-04-20T01:21:21Zen_AU
dc.date.available2022-04-20T01:21:21Zen_AU
dc.date.issued2006-12-05en_AU
dc.date.statistics2021-08-31en_AU
dc.description.abstractThe ultimate resolution in ion beam lithography can be achieved by etching the material modified by a single ion impact which has a diameter in the order of only 10 nm. The sensitivity of the resist needs to be as high as possible but also keeping the bulk etch rate at a minimum. Our study is focused on poly methyl methacrylate (PMMA) with a small bulk etch rate compared to other track detectors (e.g. CR-39). We investigated the sensitivity using 3 MeV H, 8 MeV F, 71 MeV Cu and 88 MeV I generated by ion microprobes. Precise ion counting into a spin coated PMMA film on top of an active substrate enables us to control the exact dose and fluence delivered to the PMMA from a homogenous dose down to separated single ion tracks. With homogenous irradiation, the sensitivity limit was found to be 1-2 eV/nm^3, hence the damage radius and LET determines the etchability of a single ion track. Analysis of the track radii was performed using non-contact AFM. A high aspect ratio Si nanowhisker tip was used to image the openings to the etched tracks. It was found that for up to 8 min development in a water:IPA solution holes were created for the F, Cu and I ions. The undamaged bulk PMMA is also etched at a significantly lower rate than the ion tracks and contributed to a roughening of the PMMA surface. At 16 min developing time the PMMA film was completely removed. This was attributed to a mechanical failure in the film and not gradual film etching. Hole diameter and depth has been quantitatively analysed in an effort to determine the relationship between the LET of the incident ion, the development time and the resulting hole diameter.en_AU
dc.identifier.citationAlves, A., Reichart, P., Siegele, R., Johnston, P., & Jamieson, D. (2006). Characterization of single ion tracks in PMMA created by light and heavy ion microprobes. Poster presented at the Australian Institute of Physics 17th National Congress 2006, Brisbane Convention and Exhibition Centre, Brisbane Australia, Sunday 3 - Friday 8 December 2006. Retrieved from: https://www.aip.org.au/resources/Documents/Congress/AIPCongress-2006-Program.pdfen_AU
dc.identifier.conferenceenddate8 December 2006en_AU
dc.identifier.conferencenameAustralian Institute of Physics 17th National Congress 2006en_AU
dc.identifier.conferenceplaceBrisbane, Australiaen_AU
dc.identifier.conferencestartdate3 December 2006en_AU
dc.identifier.urihttps://www.aip.org.au/resources/Documents/Congress/AIPCongress-2006-Program.pdfen_AU
dc.identifier.urihttps://apo.ansto.gov.au/dspace/handle/10238/13038en_AU
dc.language.isoenen_AU
dc.publisherAustralian Institute of Physicsen_AU
dc.subjectIonsen_AU
dc.subjectHeavy ionsen_AU
dc.subjectIon beamsen_AU
dc.subjectPMMAen_AU
dc.subjectMeV rangeen_AU
dc.subjectFilmsen_AU
dc.subjectLETen_AU
dc.titleCharacterization of single ion tracks in PMMA created by light and heavy ion microprobesen_AU
dc.typeConference Posteren_AU
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
AIPCongress-2006-Program(2).pdf
Size:
13.72 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.63 KB
Format:
Item-specific license agreed upon to submission
Description: