Improved resolution on the ANSTO microprobe and its application

dc.contributor.authorSiegele, Ren_AU
dc.contributor.authorReinhard, MIen_AU
dc.contributor.authorIonescu, Men_AU
dc.contributor.authorKachenko, AGen_AU
dc.contributor.authorCohen, DDen_AU
dc.date.accessioned2022-04-08T05:37:38Zen_AU
dc.date.available2022-04-08T05:37:38Zen_AU
dc.date.issued2009-11-25en_AU
dc.date.statistics2022-02-25en_AU
dc.descriptionThis paper is only available in print format. The Conference Proceedings are held by ANSTO Library, DDC number 543.1/11.en_AU
dc.description.abstractOne of the main aims of microbeam analysis is to achieve small spot sizes while maintaining sufficient target current. Larger target currents result in shorter measurement time and higher sensitivity for trace elements. The main factors that lead to high target currents, beside the focusing quadrupoles are the brightness of the ion source and the beam transmission through the accelerator. Using a higher brightness ion source and improving the beam transmission we have been able to to improve the resolution of the ANSTO heavy ion microprobe and considerably increase the target current. We will report on the the improved resolution and demonstrate its application in both μ-PIXE and IBIC application. With a higher brightness source, we achieved a resolution of 3 μm for μ-PIXE, while much a better resolution is possible for imaging techniques such as IBIC. The higher beam currents also allow mapping of trace elements with shorter measurement times. We will demonstrate the improved resolution on elemental maps of tissue samples from metal-hyperaccumulating plants. Individual cells can clearly be resolved in the elemental images. A resolution of approx. 1 μm has been achieved for imaging techniques such as IBIC and has been used for characterization of microdosimeters. With this resolution we were able to image devices with an active volume of 2 μm. © 2009 AINSEen_AU
dc.identifier.citationSiegele, R., Reinhard, M., Ionescu, M., Kachenko, A. & Cohen, D. D.(2009). Improved resolution on the ANSTO microprobe and its application. Poster presented at the 16th Conference on Nuclear & Complementary Techniques of Analysis, AINSE, Lucas Heights, 25-27 November 2009.en_AU
dc.identifier.conferenceenddate27 November 2009en_AU
dc.identifier.conferencename16th Conference on Nuclear & Complementary Techniques of Analysisen_AU
dc.identifier.conferenceplaceLucas Heights, NSWen_AU
dc.identifier.conferencestartdate25 November 2009en_AU
dc.identifier.urihttps://apo.ansto.gov.au/dspace/handle/10238/12977en_AU
dc.language.isoenen_AU
dc.publisherAustralian Institute of Nuclear Science and Engineering (AINSE)en_AU
dc.subjectANSTOen_AU
dc.subjectBeam analyzersen_AU
dc.subjectIon sourcesen_AU
dc.subjectAcceleratorsen_AU
dc.subjectPIXE analysisen_AU
dc.subjectResolutionen_AU
dc.subjectElementsen_AU
dc.titleImproved resolution on the ANSTO microprobe and its applicationen_AU
dc.typeConference Posteren_AU
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Cohen p.79.pdf
Size:
836.26 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.63 KB
Format:
Item-specific license agreed upon to submission
Description: