Towards real-time analysis of liquid jet alignment in SFX

dc.contributor.authorPatel, Jen_AU
dc.contributor.authorRound, Aen_AU
dc.contributor.authorPeele, AGen_AU
dc.contributor.authorMancuso, Aen_AU
dc.contributor.authorAbbey, Ben_AU
dc.date.accessioned2024-02-28T04:22:31Zen_AU
dc.date.available2024-02-28T04:22:31Zen_AU
dc.date.issued2021-08-14en_AU
dc.date.statistics2023-04-18en_AU
dc.description.abstractSerial femtosecond crystallography (SFX) enables the retrieval of the molecular structure of protein molecules at the atomic level through the measurement of large numbers of small crystals intersecting intense X-ray pulses. The method of sample delivery for SFX has a very significant impact on the success (or otherwise) of the experiment since this can impact the signal-to-noise, resolution, and amount of data that can be obtained. In particular, highly efficient sample delivery is critical, since this minimises the amount of X-ray Free Electron Laser (XFEL) beamtime required as well as reducing sample consumption and data volumes. Here we present the results from a series of liquid jet experiments performed at the European XFEL using gas focused liquid injectors, gas virtual dynamic nozzle (GVDN), and double flow focusing nozzles. Although these methods are well-established and used extensively at the European XFEL a major drawback of using these injectors is that over time the jet can become misaligned with the XFEL beam. At present, this requires regular manual monitoring in order to ensure that the relative drift of the jet with respect to the X-ray beam does not become so significant that the beam either ‘clips’ or misses the jet entirely. Manual adjustment of the liquid jet to ensure alignment with the Xray beam costs the beamline staff time, is prone to errors, and ultimately reduces the amount of useable data that is collected. In order to address the issue of jet misalignment we present a novel approach to analysing the liquid stream both with (‘hit’) and without (‘miss’) intersection by the X-ray beam using machine vision. Optical images from the from the side microscope currently used to monitor the jet are fed into our machine vision algorithm and used to classify the images as either a hit or miss. Currently we are testing the efficacy of the algorithm with a variety of nozzles and jetting conditions. The algorithm will then be incorporated into the control system at the SFX/SPB beamline at the European XFEL where it will be used to generate an ‘alignment correction’ to the stepper motors controlling the location of the nozzle within the chamber. Via a continuous feedback loop, fine adjustments will be made to the position of the liquid jet ensuring that maximum X-ray beam/liquid jet overlap is achieved. Since this process is fully automated we anticipate that it will result in a larger volume of useful data being collected without requiring any manual intervention. By increasing the efficiency and reducing the per experiment operational cost of SFX at the European XFEL ultimately more experiments can be performed. In addition, via analysis of the feedback metrology we anticipate that optimised nozzle designs and jetting conditions could be achieved further benefitting the end user. © The Authorsen_AU
dc.identifier.articlenumberC1258en_AU
dc.identifier.citationPatel, J., Round, A., Peele, A., Mancuso, A., & Anney, B. (2021). Towards real-time analysis of liquid jet alignment in SFX. Poster presented to the IUCr 2021, 25th Congress of the International Union of Crystallography, 14-22 August 2021, Prague, Czech Republic. In Acta Crystallographica Section A : Foundations and Advances, 77(a2), C1258. doi:10.1107/S0108767321084555Retrieved from:en_AU
dc.identifier.conferenceenddate2021-08-22en_AU
dc.identifier.conferencenameIUCr 2021, 25th Congress of the International Union of Crystallographyen_AU
dc.identifier.conferenceplacePrague, Czech Republicen_AU
dc.identifier.conferencestartdate2021-08-14en_AU
dc.identifier.issn2053-2733en_AU
dc.identifier.issuea2en_AU
dc.identifier.journaltitleActa Crystallographica Section A : Foundations and Advancesen_AU
dc.identifier.otherPS-54-4en_AU
dc.identifier.urihttps://doi.org/doi:10.1107/S0108767321084555en_AU
dc.identifier.urihttps://apo.ansto.gov.au/handle/10238/15473en_AU
dc.identifier.volume77en_AU
dc.language.isoenen_AU
dc.publisherInternational Union of Crystallographyen_AU
dc.subjectCrystallographyen_AU
dc.subjectProteinsen_AU
dc.subjectMeasuging instrumentsen_AU
dc.subjectX-ray diffractionen_AU
dc.subjectCrystalsen_AU
dc.subjectBeamsen_AU
dc.subjectJetsen_AU
dc.subjectAlgorithmsen_AU
dc.subjectImagesen_AU
dc.titleTowards real-time analysis of liquid jet alignment in SFXen_AU
dc.typeConference Posteren_AU
Files
Original bundle
Now showing 1 - 2 of 2
Loading...
Thumbnail Image
Name:
a60820.pdf
Size:
154.36 KB
Format:
Adobe Portable Document Format
Description:
Loading...
Thumbnail Image
Name:
a60820-2.pdf
Size:
154.36 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.63 KB
Format:
Item-specific license agreed upon to submission
Description: