Results of the CCRI(II)-S12.H-3 supplementary comparison: comparison of methods for the calculation of the activity and standard uncertainty of a tritiated-water source measured using the LSC-TDCR method

dc.contributor.authorCassette, Pen_AU
dc.contributor.authorAltzitzoglou, Ten_AU
dc.contributor.authorAnthohe, Aen_AU
dc.contributor.authorRossi, Men_AU
dc.contributor.authorArinc, Aen_AU
dc.contributor.authorCapogni, Men_AU
dc.contributor.authorGalea, Ren_AU
dc.contributor.authorGudelis, Aen_AU
dc.contributor.authorKossert, Ken_AU
dc.contributor.authorLee, KBen_AU
dc.contributor.authorLiang, Jen_AU
dc.contributor.authorNedjadi, Yen_AU
dc.contributor.authorOropesa Verdecia, Pen_AU
dc.contributor.authorShilnikova, Ten_AU
dc.contributor.authorvan Wyngaardt, WMen_AU
dc.contributor.authorZiemek, Ten_AU
dc.contributor.authorZimmerman, BEen_AU
dc.date.accessioned2021-12-01T21:52:09Zen_AU
dc.date.available2021-12-01T21:52:09Zen_AU
dc.date.issued2018-04en_AU
dc.date.statistics2021-11-12en_AU
dc.description.abstractA comparison of calculations of the activity of a 3H2O liquid scintillation source using the same experimental data set collected at the LNE-LNHB with a triple-to-double coincidence ratio (TDCR) counter was completed. A total of 17 laboratories calculated the activity and standard uncertainty of the LS source using the files with experimental data provided by the LNE-LNHB. The results as well as relevant information on the computation techniques are presented and analysed in this paper. All results are compatible, even if there is a significant dispersion between the reported uncertainties. An output of this comparison is the estimation of the dispersion of TDCR measurement results when measurement conditions are well defined. © 2017 Elsevier Ltd.en_AU
dc.identifier.citationCassette, P., Altzitzoglou, T., Antohe, A., Rossi, M., Arinc, A., Capogni, M., Galea, R. Gudelis, A., Kossert, K., Lee, K. B., Liang, J., Nedjadi, Y., Oropesa Verdecia, P., Shilnikova, T., van Wyngaardt, W., Ziemek, T., & Zimmerman, B. (2018). Results of the CCRI(II)-S12.H-3 supplementary comparison: comparison of methods for the calculation of the activity and standard uncertainty of a tritiated-water source measured using the LSC-TDCR method. Applied Radiation and Isotopes, 134, 257-262. doi:10.1016/j.apradiso.2017.07.007en_AU
dc.identifier.issn0969-8043en_AU
dc.identifier.journaltitleApplied Radiation and Isotopesen_AU
dc.identifier.pagination257-262en_AU
dc.identifier.urihttps://doi.org/10.1016/j.apradiso.2017.07.007en_AU
dc.identifier.urihttps://apo.ansto.gov.au/dspace/handle/10238/12314en_AU
dc.identifier.volume134en_AU
dc.language.isoenen_AU
dc.publisherElsevier B. V.en_AU
dc.subjectLiquid scintillatorsen_AU
dc.subjectTritiumen_AU
dc.subjectCalculation methodsen_AU
dc.subjectWateren_AU
dc.subjectDispersionsen_AU
dc.subjectDataen_AU
dc.subjectAlgorithmsen_AU
dc.titleResults of the CCRI(II)-S12.H-3 supplementary comparison: comparison of methods for the calculation of the activity and standard uncertainty of a tritiated-water source measured using the LSC-TDCR methoden_AU
dc.typeJournal Articleen_AU
Files
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.63 KB
Format:
Item-specific license agreed upon to submission
Description:
Collections