Design and first year-operation results from EMU, the high-resolution backscattering spectrometer at ANSTO

dc.contributor.authorde Souza, NRen_AU
dc.date.accessioned2021-08-24T22:34:21Zen_AU
dc.date.available2021-08-24T22:34:21Zen_AU
dc.date.issued2017-07-12en_AU
dc.date.statistics2021-08-17en_AU
dc.description.abstractANSTO recently commissioned a high-resolution neutron spectrometer, EMU, at its OPAL research reactor. The spectrometer is based on crystal backscattering, implemented through spherical focusing between a Si(111) crystal monochromator and Si(111) analyser arrays, and as first performed on the IN16 spectrometer at ILL. The incident neutron energies are modulated by fast oscillation of the monochromator, yielding a net energy transfer range of ±31 ?eV. The most unique feature of EMU is to maintain its high, 1.2 ?eV energy transfer resolution from 1.95 to 0.1 Å-1momentum transfers. Neutron events are resolved by two 3He LPSD arrays. Data analysis is carried out with the Mantid software package. Results from the first year of operation are presented to highlight performance. EMU is especially suited to characterizing diffusion processes occurring in macromolecular and functional materials e.g. polymers, proteins, lipid membranes, solid-state conductors, or molecular liquids and crystals. Most scientific user experiments to date were carried out over the accessible temperature range of 30 mK up to 800 K. Other sample environments such as controlled gas delivery, pressure, electric and magnetic fields, etc. are available or under testing. EMU presently offers a typical 1000:1 signal-to-noise ratio. Measures aimed at increasing signal-to-noise, as well as energy transfer range, are being considered to further spectrometer performance.en_AU
dc.identifier.citationde Souza, N. R. (2017). Design and first year-operation results from EMU, the high-resolution backscattering spectrometer at ANSTO. Paper presented at ICNS 2017 (International Conference on Neutron Scattering), Daejeon, South Korea, 9 to 13 July 2017. Retrieved from: http://www.icns2017.org/program.phpen_AU
dc.identifier.conferenceenddate13 July 2017en_AU
dc.identifier.conferencenameICNS 2017 (International Conference on Neutron Scattering)en_AU
dc.identifier.conferenceplaceDaejeon, South Koreaen_AU
dc.identifier.conferencestartdate9 July 2017en_AU
dc.identifier.urihttp://www.icns2017.org/program.phpen_AU
dc.identifier.urihttps://apo.ansto.gov.au/dspace/handle/10238/11469en_AU
dc.language.isoenen_AU
dc.publisherInternational Conference on Neutron Scatteringen_AU
dc.subjectANSTOen_AU
dc.subjectOPAL Reactoren_AU
dc.subjectBackscatteringen_AU
dc.subjectMonochromatorsen_AU
dc.subjectEnergy transferen_AU
dc.subjectDiffusionen_AU
dc.titleDesign and first year-operation results from EMU, the high-resolution backscattering spectrometer at ANSTOen_AU
dc.typeConference Abstracten_AU
Files
Original bundle
Now showing 1 - 2 of 2
Loading...
Thumbnail Image
Name:
11_1013 Design and first year-operation results from EMU, the high-resolution backscattering spectrometer at ANSTO.pdf
Size:
3.8 KB
Format:
Adobe Portable Document Format
Description:
Loading...
Thumbnail Image
Name:
ICNS2017_final_program.pdf
Size:
5.42 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.63 KB
Format:
Item-specific license agreed upon to submission
Description: