Repository logo


Characterization of CdMnTe radiation detectors using current and charge transients

dc.contributor.authorRafiei, Ren_AU
dc.contributor.authorReinhard, MIen_AU
dc.contributor.authorSarbutt, Aen_AU
dc.contributor.authorUxa, Sen_AU
dc.contributor.authorBoardman, DAen_AU
dc.contributor.authorWatt, GCen_AU
dc.contributor.authorBelas, Een_AU
dc.contributor.authorKim, KHen_AU
dc.contributor.authorBolotnikov, AEen_AU
dc.contributor.authorJames, RBen_AU
dc.date.accessioned2026-01-20T00:18:11Zen_AU
dc.date.issued2013-07en_AU
dc.date.statistics2023-04-20en_AU
dc.description.abstractCharge transport characteristics of Cd0.95Mn0.05Te: In radiation detectors have been evaluated by combining time resolved current transient measurements with time of flight charge transient measurements. The shapes of the measured current pulses have been interpreted with respect to a concentration of net positive space-charge, which has resulted in an electric field gradient across the detector bulk. From the recorded current pulses the charge collection efficiency of the detector was found to approach 100%. From the evolution of the charge collection efficiency with applied bias, the electron mobility-lifetime product of μnτn = (8.5 ± 0.4) × 10−4 cm2/V has been estimated. The electron transit time was determined using both transient current technique and time of flight measurements in the bias range of 100–1900 V From the dependence of drift velocity on applied electric field the electron mobility was found to be μn = (718 ± 55) cm2/(V.s) at room temperature. © 2013 Chinese Institute of Electronicsen_AU
dc.identifier.citationRafiei, R., Reinhard, M. I., Sarbutt, A., Uxa, S., Boardman, D., Watt, G. C., Belas, E., Kim, K., Bolotnikov, A. E., & James, R. B. (2013). Characterization of CdMnTe radiation detectors using current and charge transients. Journal of Semiconductors, 34(7), 073001. doi:10.1088/1674-4926/34/7/073001en_AU
dc.identifier.issn1674-4926en_AU
dc.identifier.urihttps://doi.org/10.1088/1674-4926/34/7/073001en_AU
dc.identifier.urihttps://apo.ansto.gov.au/handle/10238/16924en_AU
dc.language.isoenen_AU
dc.publisherIOPen_AU
dc.subjectRadiation detectorsen_AU
dc.subjectCadmium compoundsen_AU
dc.subjectFabricationen_AU
dc.subjectManganeseen_AU
dc.subjectTelluridesen_AU
dc.subjectCadmiumen_AU
dc.subjectElectric fieldsen_AU
dc.subjectTime-of-flight methoden_AU
dc.titleCharacterization of CdMnTe radiation detectors using current and charge transientsen_AU