dc.description.abstract | This work presents a technique for localising the endpoints of the lines of response in a PET scanner based on a continuous cylindrical shell scintillator. The technique is demonstrated by applying it to a simulation of a sensitivity-optimised continuous cylindrical shell PET system using two novel scintillator materials -a transparent ceramic garnet, GLuGAG:Ce, and a LuF3:Ce-polystyrene nanocomposite. Error distributions for the endpoints of the lines of response in the axial, tangential and radial dimension as well as overall endpoint spatial error are calculated for three source positions; the resultant distribution of error in the placement of the lines of response is also estimated. © 019 Crown | en_AU |
dc.format.medium | en_AU | |
dc.identifier.booktitle | Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) | en_AU |
dc.identifier.citation | Wilson, K. J., Alabd, R., Abolhasan, M., Franklin, D. R., & Safavi-Naeini, M. (2019, 23-27 July 2019). Localisation of the lines of response in a continuous cylindrical shell PET scanner. Paper presented to the 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 23-27 July 2019, Berlin, Germany. In 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) : Biomedical Engineering Ranging from Wellness to Intensive Care : 41st EMB Conference 2019 : July 23-27, Berlin, (pp. 4844-4850). doi: 10.1109/EMBC.2019.8856676 | en_AU |
dc.identifier.conferenceenddate | 2019-07-27 | en_AU |
dc.identifier.conferencename | 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) | en_AU |
dc.identifier.conferenceplace | Berlin, Germany | en_AU |
dc.identifier.conferencestartdate | 2019-07-23 | en_AU |
dc.identifier.isbn | 9781538613115 | en_AU |
dc.identifier.isbn | 9781538613122 | en_AU |
dc.identifier.issn | 1557-170X | en_AU |
dc.identifier.issn | 1558-4615 | en_AU |
dc.identifier.other | FrPOS-10.3 | en_AU |
dc.identifier.pagination | 4844-4850 | en_AU |
dc.identifier.placeofpublication | Piscataway, New Jersey | en_AU |
dc.identifier.uri | https://doi.org/10.1109/embc.2019.8856676 | en_AU |
dc.identifier.uri | https://apo.ansto.gov.au/handle/10238/15894 | en_AU |
dc.language | eng | en_AU |
dc.language.iso | en | en_AU |
dc.publisher | Institute of Electrical and Electronics Engineers (IEEE) | en_AU |
dc.subject | Simulation | en_AU |
dc.subject | Materials | en_AU |
dc.subject | Ceramics | en_AU |
dc.subject | Gallium | en_AU |
dc.subject | Lutetium | en_AU |
dc.subject | Nanocomposites | en_AU |
dc.title | Localisation of the lines of response in a continuous cylindrical shell PET scanner | en_AU |
dc.type | Conference Paper | en_AU |